RC IT REFROIDISSEMENT GROUPE FROID REFOIDIT A AIR AVEC FREECOOLING FR-FC-Z 1502 - 6002

Image RC IT REFROIDISSEMENT GROUPE FROID REFOIDIT A AIR AVEC FREECOOLING FR-FC-Z 1502 – 6002

FR-FC-Z 1502 - 6002
Air cooled chiller with free-cooling

product iconproduct iconproduct iconproduct iconproduct iconproduct iconproduct icon
  • format_align_leftDescription
    Outdoor unit for the production of chilled water, equipped with semi-hermetic screw compressors, R134a refrigerant, axial-fans, condensing coil with copper tubes and aluminum fins, shell and tube evaporator single pass and electronic expansion valve. Base, supporting structure and panels are of galvanized epoxy powder coated steel. The unit is supplied with anti-freeze oil and refrigerant and has been factory tested. On-site installation therefore just involves making connections to the mains power and water supplies. In free cooling mode, the liquid is cooled by outdoor air, thus lowering the load of the compressors until it is reduced to zero; this occurs already at positive outdoor temperature (T+ versions and SL-T+). The NG configuration complies with applications where it is not allowed or desired the use of ethylene glycol.

    Versions

    • T+ - Version with positive free-cooling temperature 100%
    • SL-T+ - Super low noise version with positive free-cooling temperature 100%

    Configurations

    • - - Basic function
    • NG - Function for free-cooling without use of glycole

    Features

    • ENERGY SAVING
      Energy saving guaranteed by free-cooling, which exploits the low external air temperatures; free-cooling control with optional modulating valve.
    • POSITIVE TEMPERATURE OF TOTAL FREE-COOLING
      Big heat exchangers surfaces: 100% free-cooling cooling loadsatisfied at positive environment temperature
    • WIDE RANGE
      Extended capacity range.
    • UNIQUE PROPOSAL - PATENT PENDING
      Booster function to increase chiller efficiency
    • INTEGRATED HYDRONIC GROUP
      The built-in hydronic group (optional) includes the main water circuit components. The 2 pumps are in twin configuration and available with 2 or 4-pole motor, fixed or variable speed, high or low head, to satisfy the different installation requirements.

    Accessories

    • EC fans with electronic DC brushless motor
    • Modulating valve for water temperature control in Free-Cooling mode
    • Hydronic group
    • VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation
    • Fast restart
    • Double power supply with automatic changeover (ATS) or motorized changeover
    • Compressor power factor correction
    • Set-up for remote connectivity with ModBus/Echelon protocol cards
    • Touch Screen visual display
    • Remote control keyboard (distance to 200m and to 500m)
    • Noise reducer (only on not silenced versions)

  • keyboard_hideContrôles

    Control

    • Electronic control W3000 TE
      W3000TE features a large keyboard and wide LCD display for an easy and safe access to the machine setup and a complete view of unit's status. The assessment and intervention on the unit is managed through a multi-level menu, with selectable user’s language. An optional extra is the touch screen interface: 7.0” WVGA colour display with adjustable LED backlight and front USB port. The touch screen technology allows intuitive navigation between the various screens, safe access to the data with a three-level password protection as well as the graphic display of the performance of some monitored measurements. Complete alarm management system is available, with the “black-box” and the alarm history display functions. For the systems made of several units, the adjustment of the resources is performed by optional proprietary devices. Consumption metering and performance measurement are possible and supervision can be developed via proprietary devices or the integration in third party systems by means of the most common protocols ModBus, Bacnet, Bacnet-over-IP, LonWorks. Compatibility with remote keyboard (up to 8 units). The programmable timer allows the creation of an operating profile up to 4 typical days and 10 time bands. Continuous modulation of the unit capacity, based on PID algorithms and referring to the water delivery temperature.
  • find_in_pageFiches Techniques
    openscroll to see all sizes

    Application undefined

    FR-FC-Z /T+

    1502

    1702

    1902

    2002

    2202

    2602

    2702

    3002

    3202

    3402

    3602

    3902

    4202

    4502

    4802

    5402

    6002

    openscroll to see all sizes

    Application undefined

    FR-FC-Z /SL-T+

    1502

    1702

    1902

    2002

    2202

    2602

    2702

    3002

    3202

    3402

    3602

    3902

    4202

    4502

    4802

    5402

    openscroll to see all sizes

    Application undefined

    FR-FC-Z /NG /T+

    1502

    1702

    1902

    2002

    2202

    2602

    2702

    3002

    3202

    3402

    3602

    3902

    4202

    4502

    4802

    5402

    6002

    openscroll to see all sizes

    Application undefined

    FR-FC-Z /NG /SL-T+

    1502

    1702

    1902

    2002

    2202

    2602

    2702

    3002

    3202

    3402

    3602

    3902

    4202

    4502

    4802

    5402

  • picture_as_pdfTéléchargement
    • picture_as_pdf GENERAL CATALOGUES

      IT COOLING PRODUCT GUIDE
      March 2020

      cloud_download
    • picture_as_pdf BROCHURES

      IT COOLING PRODUCT OVERVIEW
      January 2020

      cloud_download
    • picture_as_pdf BROCHURES

      RC FOR IT COOLING
      June 2019

      cloud_download
    • picture_as_pdf BROCHURES

      FR-FC-Z / FR-FC-G05-Z
      May 2019

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      IT COOLING OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      ELCA WORLD
      April 2020

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      AHU SELECTION SOFWARE
      June 2019

      cloud_download