RC IT REFROIDISSEMENT ARMOIRE DE CLIMATISATION POUR SERVEURS RACK INFORMATIQUE ET SERVEUR LAME COOLSIDE CW 0020 - 0060

Image RC IT REFROIDISSEMENT ARMOIRE DE CLIMATISATION POUR SERVEURS RACK INFORMATIQUE ET SERVEUR LAME COOLSIDE CW  0020  – 0060

COOLSIDE CW 0020 - 0060
Chilled Water Rack Cooler unit
16,1 - 74,7 kW

product iconproduct icon
  • format_align_leftDescription
    The indoor vertical air conditioning units RACK COOLER is an effective management system of the Hot Spots in the data center, ensuring low energy consumption and usage possibilities even under extremely high loads for HIGH DENSITY rack ´up and over 40 kW/m2 rack. In hydronic version where the cooling is ensured by the use of an external chiller. The use of EC fan systems, featuring last-generation electronic-switching brushless motors, assures excellent performance and low consumption. Available as standard with the dynamic management of N +1 EC fans to optimize consumption and redundancy of the cooling system. These individual units to be positioned between the racks in the row so as to act locally in order to dissipate the load of servers.

    Versions

    • IN-ROW - Basic, IN-ROW air flow configuration
    • ENCLOSURE - Basic, ENCLOSURE air flow configuration

    Features

    • EFFICIENCY
      The unit combines the efficiency of a hydronic system for the extraction of heat with the use of last generation fans EC electronic commuteted , to obtain values of EER more than 100. The reduction of the temperature of the air exhausted allows the use of water very high cooling 14-20° C by the Rack Cooler that, if on the one hand prevents unpleasant phenomena of condensation (SHR = 1), will allow the other use of only the external system in chillers Frecooling Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A.
    • FLEXIBILITY
      The InRow and Enclosure versions are both arranged with hydraulics connections and electric supply from top or bottom side, so as to allow a quick and easy installation in any condition, whether or not foreseen the presence of a raised floor.
    • IDM - INTEGRATED DYNAMIC MANAGEMENT OF TEMPERATURE
      The units are supplied with a new management algorithm called IDM-INTEGRAL DYNAMIC MANAGEMENT able to prevent stratification of temperature within the rack through the use of 4 sensors (2 on the suction and 2 on the outlet) integrated and independent on the basis the real load in the single stratified BLADE work to optimize the ventilation only when required so as to maximize energy benefits. The IDM also provides the optimal management of the outlet temperatures of the treated integrating the various resources in a DYNAMIC and INTELLIGENT way.
    • REDUNDANCY
      Both the Enclosure and InRow are developed to ensure maximum RELIABILITY 'the system by total REDUNDANCY cooling system guaranteed by the new version DUAL COIL dual power supply, dual battery raffreddamenmto and double regulating valve completely independent to ensure 100 % back up in the air conditioning system. This allows you to connect your new versionbe DUAL COIL from one side to the primary system FREECOOLING (Circuit 1) and the other to a chiller chilled water in total Back up.
    • MODULARITY
      These units, with their characteristics of dimensional standardization based on the rack, are ideal for all those datacentres where SCALABILITY of the system is a strategic factor.
    • COMPARTIZATION
      Perfect integration with systems that minimize the mixing hot and cold air between the aisles and that emphasize the efficiency of such systems.
    • INTEGRATION
      INTEGRATION with all the HYDRONIC products in the Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. range via supervision software.

  • keyboard_hideContrôles

    Control

    • EVOLUTION+
      Semi-graphic display 132 x 64 pixel, programmable software, record storage of 200 alarms, general alarm, automatic reset after blackout, integral LAN system, standby management,automatic rotation, serious alarms, operating contemporaneousness, clock function.
  • find_in_pageFiches Techniques
    openscroll to see all sizes

    Application undefined

    COOLSIDE CW / IN-ROW

    0020

    0025

    0035

    0038

    0036

    0040

    0050

    0060

    0055

    openscroll to see all sizes

    Application undefined

    COOLSIDE CW / ENCLOSURE

    0020

    0025

    0035

    0038

    0036

    0040

    0050

    0060

    0055

  • picture_as_pdfTéléchargement
    • picture_as_pdf GENERAL CATALOGUES

      IT COOLING PRODUCT GUIDE
      March 2020

      cloud_download
    • picture_as_pdf BROCHURES

      IT COOLING PRODUCT OVERVIEW
      January 2020

      cloud_download
    • picture_as_pdf BROCHURES

      RC FOR IT COOLING
      June 2019

      cloud_download
    • picture_as_pdf BROCHURES

      COOLSIDE LEGACY
      May 2018

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      IT COOLING OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      ELCA WORLD
      April 2020

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      AHU SELECTION SOFWARE
      June 2019

      cloud_download