NECS-Y 0202T - 0612T
Chiller, air source for outdoor installation
47,8 - 159 kW
-
format_align_leftDescriptionOutdoor unit for the production of chilled water with hermetic rotary Scroll compressors, axialflow fans, shell and tubes exchanger and thermostatic expansion valve. External panels in Peraluman and structure in aluminium sections. The range is equipped with two compressors on two independent refrigerant circuits.
Versions
- B - Basic
- LN - Low noise
- SL - Super-low noise version
- HT - High efficiency, high outdoor temperature version
Configurations
- - - Basic function
Features
- EXCHANGER
The shell and tube exchanger allows to achieve the highest flexibility on the unit’s installation, keeping at the minimum level the pressure drops on the hydronic side, thus representing the best choice for all the hydronic applications on the process market. - MAXIMUM RELIABILITY
Unit with two independent refrigerant circuit, designed to ensure maximum efficiency at full load, ensuring uninterrupted operation even in the event of temporary stop of one of the two circuits. - INTEGRATED HYDRONIC GROUP
The built-in hydronic module includes the main water circuit components; it is available in various configurations with one or two pumps with high or low head.
Accessories
- Traditional coils available with prepainted fins or Fin Guard Silver protective treatment.
- Copper-Copper heat exchanger coils
- Compressor power factor correction
- Soft start
- Compressor suction and discharge valves
- High and low pressure gauges
- Compact keyboard with LCD display and multi-language user interface (referred to the shown picture)
- Hydronic group
- B - Basic
-
keyboard_hideContrôles
Control
- Electronic control W3000
The W3000 controller offers advanced functions and algorithms. The Base keyboard features an easy-to-use interface that allows consulting and intervening on the unit by means of a multi-level menu. The Compact keyboard (optional) has a complete LCD display with an interface available in three languages: Italian, English and a further language among French, Spanish, German, Russian and Swedish. The alarm history display function can be enable by installing a real-time clock (optional) (only with Compact keyboard). The regulation is based on the patented “Quickmind” water temperature regulation logic uses self-adapting control to maintain flow temperatures and optimise performance even in low water content scenarios. As an alternative, the proportional or proportional-integral regulations are also available. Optional proprietary devices can perform the adjustment of the resources in systems made of several units. Consumption metering and performance measurement are possible as well. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, LonWorks. Compatibility with the remote keyboard (up to 8 units) (only with Compact keyboard). The defrosting (air source reversible unit only) follows a proprietary self-adaptive logic, which features the monitoring of several operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.
- Electronic control W3000
-
find_in_pageFiches Techniquesopenscroll to see all sizes
Application undefined
NECS-Y / B
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(7)
kW
SEPR HT
(7)(9)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(8)
kW
SEPR MT
(8)(9)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202T
0252T
0302T
0352T
0412T
0452T
0512T
0552T
0612T
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
53,03
58,14
76,00
86,81
96,90
112,3
126,6
144,9
158,6
18,29
21,51
27,85
31,90
36,31
39,67
43,73
50,17
58,64
2,896
2,702
2,734
2,721
2,669
2,829
2,897
2,886
2,706
3,720
3,470
3,520
3,490
3,410
3,590
3,650
3,660
3,440
52,90
58,00
75,80
86,50
96,70
112,0
126,3
144,5
158,1
2,880
2,680
2,710
2,690
2,650
2,800
2,870
2,850
2,670
3,680
3,410
3,450
3,400
3,360
3,510
3,590
3,580
3,370
C
D
C
D
D
C
C
C
D
52,90
58,00
75,80
86,50
96,70
112,0
126,3
144,5
158,1
5,01
4,61
4,65
4,60
4,56
4,73
4,80
4,82
4,56
28,30
31,00
42,60
48,20
53,40
61,90
69,90
79,60
87,70
3,32
3,12
3,27
3,24
3,19
3,23
3,23
3,30
3,23
2,536
2,780
3,634
4,151
4,634
5,372
6,055
6,929
7,584
6,25
7,64
13,1
17,2
12,8
17,2
15,7
21,7
25,9
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
9,50
10,2
12,6
13,3
16,0
17,3
21,8
24,0
24,1
53
53
53
54
54
54
55
55
55
85
85
85
86
86
86
87
87
87
2195
2195
2195
2195
2745
2745
3245
3245
3245
1120
1120
1120
1120
1120
1120
1120
1120
1120
1465
1465
1465
1465
1465
1465
1665
1665
1665
625
625
665
765
920
990
1135
1180
1155
openscroll to see all sizesApplication undefined
NECS-Y / LN
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(7)
kW
SEPR HT
(7)(9)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(8)
kW
SEPR MT
(8)(9)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202T
0252T
0302T
0352T
0412T
0452T
0512T
0552T
0612T
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
50,65
57,60
74,19
84,40
96,38
108,8
122,0
138,8
150,9
18,92
21,23
28,60
33,66
37,07
41,41
45,91
53,09
62,43
2,683
2,717
2,594
2,504
2,598
2,628
2,658
2,614
2,418
3,500
3,510
3,370
3,220
3,330
3,360
3,380
3,340
3,110
50,60
57,50
74,00
84,20
96,20
108,5
121,7
138,4
150,4
2,670
2,700
2,570
2,480
2,580
2,600
2,640
2,590
2,390
3,460
3,460
3,300
3,170
3,270
3,300
3,320
3,280
3,040
D
C
D
E
D
D
D
D
E
50,60
57,50
74,00
96,20
108,5
121,7
138,4
4,78
4,72
4,51
4,52
4,51
4,50
4,51
27,30
30,80
42,00
47,30
53,30
60,50
68,00
77,20
84,60
3,26
3,20
3,21
3,04
3,16
3,15
3,11
3,17
3,02
2,422
2,755
3,548
4,036
4,609
5,201
5,834
6,637
7,214
5,70
7,50
12,5
16,3
12,7
16,2
14,6
19,9
23,5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
9,50
10,2
12,6
13,3
16,0
17,3
21,8
24,0
24,1
48
48
49
51
51
51
52
52
52
80
80
81
83
83
83
84
84
84
2195
2195
2745
2745
2745
2745
3245
3245
3245
1120
1120
1120
1120
1120
1120
1120
1120
1120
1465
1465
1465
1665
1665
1665
1665
1665
1665
625
650
715
840
965
1025
1135
1180
1155
openscroll to see all sizesApplication undefined
NECS-Y / SL
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(7)
kW
SEPR HT
(7)(9)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(8)
kW
SEPR MT
(8)(9)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202T
0252T
0302T
0352T
0412T
0452T
0512T
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
47,79
55,45
69,95
85,39
96,82
106,1
117,5
20,32
22,60
30,89
33,64
37,35
43,22
48,06
2,355
2,456
2,262
2,542
2,595
2,456
2,443
3,130
3,190
3,000
3,250
3,300
3,140
3,140
47,70
55,40
69,70
85,20
96,60
105,8
117,2
2,340
2,440
2,250
2,520
2,570
2,430
2,420
3,090
3,140
2,930
3,190
3,250
3,090
3,090
E
E
F
D
D
E
E
26,20
29,80
40,50
47,70
53,40
59,50
66,10
3,04
2,97
2,98
3,02
3,06
2,97
2,98
2,286
2,652
3,345
4,083
4,630
5,075
5,617
5,08
6,95
11,1
16,7
12,8
15,4
13,5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
11,7
11,7
14,6
16,4
20,1
20,6
21,2
45
46
46
49
49
49
50
77
78
78
81
81
81
82
2195
2745
2745
3245
3245
3245
3245
1100
1100
1100
1100
1100
1100
1100
1465
1465
1465
1665
1665
1665
1665
650
700
750
915
1050
1075
1115
openscroll to see all sizesApplication undefined
NECS-Y / HT
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(7)
kW
SEPR HT
(7)(9)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(8)
kW
SEPR MT
(8)(9)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202T
0252T
0302T
0352T
0412T
0452T
0512T
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
54,97
61,58
80,62
91,43
104,3
115,7
129,9
17,33
20,30
25,89
30,54
33,67
38,57
42,22
3,179
3,034
3,112
2,997
3,095
2,997
3,078
4,070
3,810
3,930
3,760
3,870
3,760
3,860
54,90
61,50
80,40
91,10
104,0
115,4
129,6
3,160
3,010
3,080
2,960
3,060
2,960
3,050
3,990
3,750
3,850
3,670
3,780
3,690
3,790
A
B
B
B
B
B
B
54,90
61,50
80,40
91,10
104,0
115,4
129,6
5,39
5,00
5,05
4,85
5,01
4,92
5,05
29,10
32,70
44,30
49,80
56,10
63,10
71,20
3,51
3,26
3,46
3,30
3,35
3,29
3,32
2,629
2,945
3,856
4,372
4,987
5,532
6,210
6,72
8,58
14,7
19,1
14,9
18,3
16,5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
11,7
11,7
14,6
16,4
20,1
20,6
21,2
53
54
54
55
55
55
55
85
86
86
87
87
87
87
2195
2745
2745
3245
3245
3245
3245
1120
1120
1120
1120
1120
1120
1120
1465
1465
1465
1665
1665
1665
1665
650
700
750
915
1050
1075
1115
-
picture_as_pdfTéléchargement
-
picture_as_pdf
GENERAL CATALOGUES
COMFORT PRODUCT GUIDE
cloud_download
May 2020 -
picture_as_pdf
GENERAL CATALOGUES
PROCESS PRODUCT GUIDE
cloud_download
March 2020 -
picture_as_pdf
BROCHURES
IT COOLING PRODUCT OVERVIEW
cloud_download
January 2020 -
picture_as_pdf
BROCHURES
NECS-Y / NX-Y
cloud_download
June 2018 -
picture_as_pdf
PROJECT FOCUS
CAPITEC
cloud_download
August 2020 -
picture_as_pdf
PROJECT FOCUS
TOYOTA MOTOR ITALIA
cloud_download
August 2020 -
picture_as_pdf
PRODUCT OVERVIEW
COMFORT OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
PRODUCT OVERVIEW
PROCESS OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 2015/1095
NECS-Y 0202T - 0612T SEPR-MT
cloud_download
March 2018 -
picture_as_pdf
SELECTION SOFTWARE
ELCA WORLD
cloud_download
April 2020 -
picture_as_pdf
SELECTION SOFTWARE
AHU SELECTION SOFWARE
cloud_download
June 2019
-
picture_as_pdf
GENERAL CATALOGUES