ERACS2-WQ-Y 0802 - 1502
INTEGRA unit for 4-pipe systems, water source
189 - 363 kW
-
format_align_leftDescriptionMulti-purpose indoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent water circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching. Each circuit works with a semi-hermetic screw compressor using R134a, and three tube nest heat exchangers, a cold exchanger on the user side shared by both circuits that acts as an evaporator in the production of cold water, a heat exchanger on the user side that words as a condenser in the production of hot water, and a source side exchanger that works as either condenser or evaporator as required by the loads.
Versions
- - - Basic
Features
- UNIQUE PROPOSAL
Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting - ENERGY SAVING
Energy saving guaranteed by the advanced operation’s logic. The best operation mode is set completely automatically and independently by the unit’s controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be - WIDE OPERATING RANGE
Supply of hot water in use up to 60°C, offering maximum versatility with respect to different plant engineering solutions - INTEGRATED CONDENSATION´S CONTROL
A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request.
Accessories
- Integral acoustical enclosure (type base or plus)
- Several devices for condensation´s control
- Electronic expansion valve
- Set-up for remote connectivity with ModBus/Echelon protocol cards
- - - Basic
-
keyboard_hideContrôles
Control
- Electronic control W3000TE
W3000TE controller feature a large format keyboard with wide LCD display in order to ensure an easy access to the machine setup and a complete view of unit's status. The assessment and intervention on the unit is managed through a multi-level menu, with selectable user’s language. The led icons immediately show the operating status of various components.As alternative, the innovative KIPlink user interface allows one to operate on the unit directly from the smartphone or tablet. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. Complete alarm management system is available, with the “black-box” and the alarm history display functions. Optional proprietary devices adjust the resources in systems made of several units. Consumption metering and performance measurement are available and supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, LonWorks. Compatibility with the remote keyboard (up to 8 units). The programmable timer manages a weekly schedule organised into time bands (up to 10 daily time bands associated with different operating set points) to optimise unit performance by minimising power consumption during periods of inactivity. Proprietary self-adaptive logic for the defrosting features the monitoring of several operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.
- Electronic control W3000TE
-
find_in_pageFiches Techniquesopenscroll to see all sizes
Application undefined
ERACS2-WQ-Y
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
HEATING ONLY (GROSS VALUE)
Total heating capacity
(3)
kW
Total power input
(3)
kW
COP
(3)
kW/kW
HEATING ONLY (EN14511 VALUE)
Total heating capacity
(2)(3)
kW
COP
(2)(3)
kW/kW
COOLING WITH TOTAL HEAT RECOVERY
Cooling capacity
(4)
kW
Total power input
(4)
kW
Recovery heat exchanger capacity
(4)
kW
TER
kW/kW
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(5)
kW
SEPR HT
(5)(7)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(6)
kW
SEPR MT
(6)(7)
SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013)
PDesign
(8)
kW
SCOP
(8)(10)
Performance ηs
(8)(11)
%
Seasonal efficiency class
(8)
PDesign
(9)
kW
SCOP
(9)(10)
Performance ηs
(9)(11)
%
Seasonal efficiency class
(9)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
HEAT EXCHANGER SOURCE SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
HEAT EXCHANGER USER SIDE IN HEATING
Water flow
(4)
l/s
Pressure drop at the heat exchanger
(4)
kPa
HEAT EXCHANGER SOURCE SIDE IN HEATING
Water flow
(3)
l/s
Pressure drop at the heat exchanger
(3)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(12)
dB(A)
Sound power level in cooling
(13)(14)
dB(A)
Sound power level in heating
(13)(15)
dB(A)
SIZE AND WEIGHT
A
(16)
mm
B
(16)
mm
H
(16)
mm
Operating weight
(16)
kg
0802
1002
1102
1302
1502
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
189,4
234,2
268,0
317,9
363,4
35,74
44,93
50,61
59,66
68,69
5,305
5,216
5,296
5,325
5,290
182,0
224,9
256,9
305,5
348,9
4,600
4,540
4,530
4,610
4,610
205,4
254,8
291,2
344,1
392,8
45,73
56,90
65,83
76,27
86,86
4,495
4,478
4,426
4,510
4,520
206,1
255,8
292,6
345,5
394,2
4,320
4,280
4,190
4,290
4,320
162,4
201,3
229,3
272,4
311,2
45,73
56,90
65,83
76,27
86,86
205,4
254,8
291,2
344,1
392,8
8,046
8,014
7,910
8,081
8,101
169,7
3,44
249
309
353
418
5,59
5,56
5,18
5,45
215
214
199
210
-
-
-
-
220
274
315
368
4,33
4,46
3,97
4,26
165
170
151
162
-
-
-
-
8,732
10,79
12,33
14,66
16,73
25,7
32,5
43,4
37,6
33,9
10,51
13,02
14,86
17,62
20,13
37,2
47,2
62,9
54,3
49,1
9,913
12,30
14,06
16,61
18,96
33,1
42,1
56,3
48,3
43,5
5,548
6,877
7,835
9,308
10,63
10,4
13,2
17,5
15,2
13,7
2
2
2
2
2
2
2
2
2
2
40,0
46,0
52,0
58,0
75,0
62
63
65
65
65
94
95
97
97
97
94
95
97
97
0
3680
3680
3680
3680
3680
1170
1170
1170
1170
1170
1950
1950
1950
1950
1950
2420
2470
2880
3580
3690
-
picture_as_pdfTéléchargement
-
picture_as_pdf
GENERAL CATALOGUES
COMFORT PRODUCT GUIDE
cloud_download
May 2020 -
picture_as_pdf
GENERAL CATALOGUES
PROCESS PRODUCT GUIDE
cloud_download
March 2020 -
picture_as_pdf
BROCHURES
IT COOLING PRODUCT OVERVIEW
cloud_download
January 2020 -
picture_as_pdf
BROCHURES
INTEGRA FULL LINE BROCHURE
cloud_download
November 2019 -
picture_as_pdf
BROCHURES
INTEGRA PROCESS
cloud_download
July 2019 -
picture_as_pdf
PROJECT FOCUS
CAPITEC
cloud_download
August 2020 -
picture_as_pdf
PROJECT FOCUS
TOYOTA MOTOR ITALIA
cloud_download
August 2020 -
picture_as_pdf
PRODUCT OVERVIEW
COMFORT OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
PRODUCT OVERVIEW
PROCESS OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 2015/1095
ERACS2-WQ-Y 0802 - 1502 SEPR-MT
cloud_download
March 2018 -
picture_as_pdf
SELECTION SOFTWARE
ELCA WORLD
cloud_download
April 2020 -
picture_as_pdf
SELECTION SOFTWARE
AHU SELECTION SOFWARE
cloud_download
June 2019
-
picture_as_pdf
GENERAL CATALOGUES