RC - CLIMAVENETA PROCESS POMPE A CHALEUR AIR/EAU, CHAUD SEUL i-KI-MTD-Y 0075t - 0151t

Image RC – CLIMAVENETA PROCESS POMPE A CHALEUR AIR/EAU, CHAUD SEUL i-KI-MTD-Y 0075t – 0151t

i-KI-MTD-Y 0075t - 0151t
Air cooled heat pump only heating, with axial fans and inverter driven compressor, for heating water up to 60°C.
21,6 - 44,4 kW

product iconproduct iconproduct iconproduct iconproduct iconproduct iconproduct icon
  • format_align_leftDescription
    The system is based on a packaged external units with integrated hydronic module and an internal unit with the electronic regulation. The heat pump provides heating and domestic hot water production. Particular care is taken of winter mode, that thanks to the Inverter technology is guaranteed beyond traditional units working limits, water production up to60°C. The heating only heat pump features high seasonal efficiency in heating, using DC inverter technology to modulate compressor operation and deliver the exact amount of energy based on the actual needs of the installation. The units can be coupled with traditional systems or radiant panels, guaranteeing always a very high energy efficiency. Intallation is strongly simplified thanks to the integrated hydronic module.

    Versions

    • B - Basic

    Features

    • WIDE RANGE
      Extended capacity range.
    • SYSTEM EFFICIENCY
      The unit is designed as a system: all components are regulated using proprietary control’s logic for the highest efficiency.
    • HIGH EFFICIENCY AT PARTIAL LOAD
      High seasonal efficiency in both heating and cooling mode, using DC inverter technology to modulate compressor operation and deliver the exact amount of energy based on the actual needs of the installation. High efficiency for low energy consumption during the operating hours.
    • HIGH EFFICIENCY COMPONENTS
      In terms of improving performance and reducing power consumption, the electronic thermostatic valve is an important component that maximises system efficiency, same for the choise the hydronic kit with inverter water pump (optional) and the modulating the fans speed.
    • EXTENSIVE OPERATING LIMITS
      Particular care is taken for winter mode, that thanks to inverter technology is guaranteed beyond traditional units working limits, supplying hot water up to 60°C and down to -20°external air.

    Accessories

    • Integrated hydronic module with on/off pump or high efficiency inverter pump
    • Wired room terminal with backlit display, and with temperature and umidity probe
    • Extension module for system configuration
    • Three-way valve for domestic hot water
    • Electric heater of integration for the heating system
    • Electric heater for hot water cylinder, of integration and for anti-legionellosis
    • Cascade management kit
    • Serial card RS485 for ModBus
    • Buffer tank 35,100,200 liters
    • Hot water cylinder 300,500 liters
    • 300 liters thermal store for domestic hot water, for DOMH2O kit
    • 300,500,1000 liters thermal store for domestic hot water with solar heat exchanger, for DOMH2O kit
    • DOMH2O15 e DOMH2O24 kit for domestic hot water with external plate heat exchanger and pump
    • Copper-Copper heat exchanger coils
    • Copper-Aluminum heat exchanger coils with epoxy treatment
    • Electric heater for the base and for condensate collecting tray to avoid freezing

  • keyboard_hideContrôles

    Control

    • NADISYSTEM
      Electronic control that provides great application flexibility and dynamic control of delivery temperature water, optimizing indoor comfort and increasing the energy efficiency. The electronic board allows you to manage: -Wired remote control, backlit display and with temperature probe and humidity probe -Outdoor temperature sensor for water plant side modular set point compensation -A zone of direct heating for radiator, floor heating or fan coil and a zone with mix valve for floor heating -Electrical heating element for possible integration and anti-legionella cycle for cylinder -Boiler or electric heater in substitution or in addition -Up to 6 time bands can be programmed -Up to 4 heat pump in cascade (with N-CM component) -Several solutions through appropriate configurations of the controller and use of dedicated extension modules (accessorie), up to 5 zones.
  • find_in_pageFiches Techniques
    openscroll to see all sizes

    Application undefined

    i-KI-MTD-Y 0075-0151

    0075t

    0091t

    0095t

    0101t

    0121t

    0135t

    0151t

  • picture_as_pdfTéléchargement
    • picture_as_pdf GENERAL CATALOGUES

      COMFORT PRODUCT GUIDE
      May 2020

      cloud_download
    • picture_as_pdf GENERAL CATALOGUES

      PROCESS PRODUCT GUIDE
      March 2020

      cloud_download
    • picture_as_pdf BROCHURES

      IT COOLING PRODUCT OVERVIEW
      January 2020

      cloud_download
    • picture_as_pdf PROJECT FOCUS

      CAPITEC
      August 2020

      cloud_download
    • picture_as_pdf PROJECT FOCUS

      TOYOTA MOTOR ITALIA
      August 2020

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      COMFORT OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      PROCESS OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      ELCA WORLD
      April 2020

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      AHU SELECTION SOFWARE
      June 2019

      cloud_download