NX-N-Y 0604P - 1204P
Reversible unit, air source for outdoor installation
148 - 319 kW
-
format_align_leftDescriptionOutdoor reversible unit for the production of chilled/hot water with hermetic rotary Scroll compressors, ozone-friendly refrigerant R410A, axial-flow fans, copper tubes aluminum fins air coils, braze-welded plate-type exchanger and thermostatic expansion valve. External panels in pre-clad sheet steel and base in galvanised steel with paint finish. The range is composed by units equipped with four compressors in tandem configuration on two independent refrigerant circuits.
Versions
- K - Key efficiency, compact version
- LN-K - Low Noise, Key efficiency and compact version
- SL-K - Super Low noise, Key efficiency and compact version
Configurations
- - - Basic function
- D - Partial condensing heat recovery function
Features
- REFRIGERANT GAS R410A
The use of R410A allowed to achive better energy efficiencies with environment full respect (ODP = 0) - INTEGRATED HYDRONIC GROUP
The optional built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head.
Accessories
- Set-up for remote connectivity with ModBus/Echelon protocol cards
- Remote control keyboard (distance to 200m and to 500m)
- Soft starters
- Rubber anti-vibration mounting kit. Spring anti-vibration mounting kit (4 compressors models only)
- K - Key efficiency, compact version
-
keyboard_hideContrôles
Control
- W3000SE Compact
W3000SE Compact offers advanced functions and algorithms. The keypad features an easy-to-use interface and a LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. Regulation based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. The diagnostics includes a complete alarm management, with the "black-box" and alarm logging functions for enhanced analysis of the unit operation. For multiple units’ systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. - Compatibility with the remote keyboard managing up to 10 units. - Internal real time clock available for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.
- W3000SE Compact
-
find_in_pageFiches Techniquesopenscroll to see all sizes
Application undefined
NX-N-Y / K
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
HEATING ONLY (GROSS VALUE)
Total heating capacity
(3)
kW
Total power input
(3)
kW
COP
(3)
kW/kW
HEATING ONLY (EN14511 VALUE)
Total heating capacity
(2)(3)
kW
COP
(2)(3)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(4)
kW
SEPR HT
(4)(6)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(5)
kW
SEPR MT
(5)(6)
SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013)
PDesign
(7)
kW
SCOP
(7)(8)
Performance ηs
(7)(9)
%
Seasonal efficiency class
(7)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
HEAT EXCHANGER USER SIDE IN HEATING
Water flow
(3)
l/s
Pressure drop at the heat exchanger
(3)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(10)
dB(A)
Sound power level in cooling
(11)(12)
dB(A)
Sound power level in heating
(11)(13)
dB(A)
SIZE AND WEIGHT
Operating weight
(14)
kg
A
(14)
mm
B
(14)
mm
H
(14)
mm
0604P
0704P
0804P
0904P
1004P
1104P
1204P
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
160,1
185,8
211,0
245,2
274,1
298,0
319,3
56,89
67,41
75,89
88,76
99,42
106,4
115,9
2,814
2,757
2,780
2,761
2,758
2,801
2,755
3,870
4,010
4,070
3,950
3,990
4,050
4,040
159,4
185,0
210,1
244,1
272,9
296,9
318,0
2,770
2,710
2,740
2,720
2,710
2,760
2,710
3,700
3,830
3,890
3,770
3,810
3,880
3,870
C
C
C
C
C
C
C
173,5
201,7
230,4
271,3
299,5
324,0
344,6
56,39
66,40
75,45
89,20
98,31
105,7
112,8
3,076
3,038
3,056
3,041
3,047
3,065
3,055
174,4
202,6
231,5
272,7
301,0
325,4
346,3
3,050
3,010
3,030
3,010
3,020
3,040
3,030
B
B
B
B
B
B
B
127
148
172
200
226
242
260
3,23
3,27
3,27
3,21
3,24
3,26
3,21
126
128
128
125
126
127
125
-
-
-
-
-
-
-
7,655
8,885
10,09
11,73
13,11
14,25
15,27
42,5
43,2
44,9
49,2
49,2
43,7
50,1
8,375
9,738
11,12
13,09
14,45
15,64
16,64
50,9
51,9
54,5
61,3
59,8
52,6
59,5
4
4
4
4
4
4
4
2
2
2
2
2
2
2
35,8
55,6
79,1
79,2
82,8
104
104
73
72
73
74
75
75
75
92
92
93
94
95
95
95
92
92
93
94
95
95
95
1640
1990
2120
2360
2500
2850
2880
3110
4110
4110
4110
4110
5110
5110
2220
2220
2220
2220
2220
2220
2220
2150
2150
2150
2150
2150
2150
2150
openscroll to see all sizesApplication undefined
NX-N-Y / LN-K
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
HEATING ONLY (GROSS VALUE)
Total heating capacity
(3)
kW
Total power input
(3)
kW
COP
(3)
kW/kW
HEATING ONLY (EN14511 VALUE)
Total heating capacity
(2)(3)
kW
COP
(2)(3)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(4)
kW
SEPR HT
(4)(6)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(5)
kW
SEPR MT
(5)(6)
SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013)
PDesign
(7)
kW
SCOP
(7)(8)
Performance ηs
(7)(9)
%
Seasonal efficiency class
(7)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
HEAT EXCHANGER USER SIDE IN HEATING
Water flow
(3)
l/s
Pressure drop at the heat exchanger
(3)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(10)
dB(A)
Sound power level in cooling
(11)(12)
dB(A)
Sound power level in heating
(11)(13)
dB(A)
SIZE AND WEIGHT
Operating weight
(14)
kg
A
(14)
mm
B
(14)
mm
H
(14)
mm
0604P
0704P
0804P
0904P
1004P
1104P
1204P
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
152,7
174,4
200,7
234,3
258,2
282,8
303,1
56,90
68,54
78,32
90,02
101,4
108,7
119,2
2,684
2,546
2,563
2,603
2,546
2,602
2,543
3,960
4,080
4,120
4,080
4,020
4,060
4,050
152,0
173,7
199,9
233,4
257,2
281,8
301,9
2,640
2,510
2,530
2,570
2,510
2,570
2,510
3,780
3,900
3,950
3,900
3,860
3,910
3,880
D
D
D
D
D
D
D
165,4
192,2
221,4
255,0
283,8
310,1
329,1
52,69
62,99
71,89
83,89
92,88
100,4
107,3
3,139
3,051
3,079
3,039
3,055
3,089
3,067
166,2
193,1
222,4
256,2
285,1
311,4
330,6
3,110
3,020
3,050
3,010
3,030
3,060
3,040
B
B
B
B
B
B
B
126
132
170
196
223
239
257
3,34
3,30
3,51
3,37
3,38
3,42
3,43
130
129
137
132
132
134
134
-
-
-
-
-
-
-
7,304
8,339
9,597
11,20
12,35
13,52
14,49
38,7
38,0
40,6
44,9
43,7
39,3
45,2
7,982
9,279
10,69
12,31
13,70
14,97
15,88
46,2
47,1
50,3
54,2
53,7
48,2
54,3
4
4
4
4
4
4
4
2
2
2
2
2
2
2
35,8
55,6
79,1
79,2
82,8
104
104
67
66
67
68
69
70
70
86
86
87
88
89
90
90
87
87
88
89
90
91
91
1690
2040
2170
2410
2550
2900
2930
3110
4110
4110
4110
4110
5110
5110
2220
2220
2220
2220
2220
2220
2220
2150
2150
2150
2150
2150
2150
2150
openscroll to see all sizesApplication undefined
NX-N-Y / SL-K
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
HEATING ONLY (GROSS VALUE)
Total heating capacity
(3)
kW
Total power input
(3)
kW
COP
(3)
kW/kW
HEATING ONLY (EN14511 VALUE)
Total heating capacity
(2)(3)
kW
COP
(2)(3)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(4)
kW
SEPR HT
(4)(6)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(5)
kW
SEPR MT
(5)(6)
SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013)
PDesign
(7)
kW
SCOP
(7)(8)
Performance ηs
(7)(9)
%
Seasonal efficiency class
(7)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
HEAT EXCHANGER USER SIDE IN HEATING
Water flow
(3)
l/s
Pressure drop at the heat exchanger
(3)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(10)
dB(A)
Sound power level in cooling
(11)(12)
dB(A)
Sound power level in heating
(11)(13)
dB(A)
SIZE AND WEIGHT
Operating weight
(14)
kg
A
(14)
mm
B
(14)
mm
H
(14)
mm
0604P
0704P
0804P
0904P
1004P
1104P
1204P
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
148,0
175,5
201,7
232,0
255,7
281,1
303,4
57,83
68,54
78,93
88,21
100,4
110,5
119,3
2,561
2,562
2,556
2,630
2,547
2,544
2,543
4,070
4,070
4,110
4,120
4,120
4,090
4,090
147,4
174,8
200,9
231,1
254,7
280,1
302,2
2,520
2,530
2,520
2,590
2,510
2,510
2,510
3,900
3,890
3,930
3,930
3,950
3,940
3,920
D
D
D
D
D
D
D
160,2
193,0
223,2
256,8
282,7
307,3
330,1
51,18
63,61
72,49
82,20
91,24
100,2
108,2
3,129
3,035
3,079
3,124
3,100
3,067
3,051
160,9
193,9
224,2
258,0
284,0
308,5
331,6
3,100
3,010
3,050
3,090
3,070
3,040
3,020
B
B
B
B
B
B
B
125
135
172
197
219
239
258
3,45
3,24
3,47
3,54
3,46
3,40
3,41
135
127
136
139
136
133
133
-
-
-
-
-
-
-
7,079
8,392
9,645
11,10
12,23
13,44
14,51
36,4
38,5
41,0
44,0
42,8
38,9
45,3
7,734
9,316
10,78
12,40
13,65
14,83
15,93
43,4
47,5
51,2
55,0
53,3
47,3
54,6
4
4
4
4
4
4
4
2
2
2
2
2
2
2
35,8
59,6
79,1
79,2
82,8
104
104
63
63
63
64
65
66
67
82
83
83
84
85
86
87
83
84
84
85
86
87
88
1690
2130
2260
2690
2830
3020
3040
3110
4110
4110
5110
5110
5110
5110
2220
2220
2220
2220
2220
2220
2220
2150
2150
2150
2150
2150
2150
2150
-
picture_as_pdfTéléchargement
-
picture_as_pdf
GENERAL CATALOGUES
COMFORT PRODUCT GUIDE
cloud_download
May 2020 -
picture_as_pdf
GENERAL CATALOGUES
PROCESS PRODUCT GUIDE
cloud_download
March 2020 -
picture_as_pdf
BROCHURES
IT COOLING PRODUCT OVERVIEW
cloud_download
January 2020 -
picture_as_pdf
PROJECT FOCUS
CAPITEC
cloud_download
August 2020 -
picture_as_pdf
PROJECT FOCUS
TOYOTA MOTOR ITALIA
cloud_download
August 2020 -
picture_as_pdf
PRODUCT OVERVIEW
COMFORT OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
PRODUCT OVERVIEW
PROCESS OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 813/2013
NX-N-G06-Y 4-COMPRESSOR UNITS SCOP (EC FANS; PLATES)
cloud_download
November 2019 -
picture_as_pdf
TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 813/2013
NX-N-G06-Y 4-COMPRESSOR UNITS SCOP (PLATES)
cloud_download
November 2019 -
picture_as_pdf
SELECTION SOFTWARE
ELCA WORLD
cloud_download
April 2020 -
picture_as_pdf
SELECTION SOFTWARE
AHU SELECTION SOFWARE
cloud_download
June 2019
-
picture_as_pdf
GENERAL CATALOGUES