                        NX-Q-Y 0152P - 0602P
                        INTEGRA unit for 4-pipe systems, air source for outdoor installation
43,9 - 169 kW
                    
                    
                    
                    
                    
                    
                - 
                      format_align_leftDescriptionMulti-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. Unit with two independent refrigerant circuits, each circuit works with an hermetic rotary Scroll compressors using R410A, axial fans, braze-welded plate-type exchanger and thermal expansion valve.Versions - - - Basic
- SL - Super-low noise version
 Configurations - - - Basic function
 Features - UNIQUE PROPOSAL
 Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting
- ENERGY SAVING
 Energy saving guaranteed by the advanced operation’s logic. The best operation mode is set completely automatically and independently by the unit’s controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be
- ErP READY
 The highest level of efficiency at part load can meet and exceed the minimum seasonal efficiency for heating, SCOP (only for reversible units) and for process cooling, SEPR, in accordance with the eco-sustainable design requirements for all products using energy.
- INTEGRATED HYDRONIC GROUP
 The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving both low or high head, fixed or variable speed, available for both plant and recovery circuits (up to 4 pumps).
- WIDE OPERATING RANGE
 The accurate condensation control (variable fan speed regulation as per standard on every model) and devoted kits allow unit's operation from -10°C to 46°C of outdoor air temperature, from -8°C to 18°C of evaporator leaving water temperature and hot water up to 55°C.
 Accessories - Touch Screen visual display
- Set-up for remote connectivity with ModBus/Echelon protocol cards
- Hydronic kit available in different configurations with 1 or 2 pumps fixed speed or variable speed, for achieving both low or high head, available for both plant and recovery circuits.
- EC fans with electronic DC brushless motor
- LOW NOISE KIT (only on no silenced versions)
- Soft starters
- Electronic expansion valve
 
 
- - - Basic
- 
                      keyboard_hideContrôlesControl - Electronic control W3000TE
 W3000TE controller feature a large format keyboard with wide LCD display in order to ensure an easy access to the machine setup and a complete view of unit's status. The assessment and intervention on the unit is managed through a multi-level menu, with selectable user’s language. The led icons immediately show the operating status of various components.As alternative, the innovative KIPlink user interface allows one to operate on the unit directly from the smartphone or tablet. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. Complete alarm management system is available, with the “black-box” and the alarm history display functions. Optional proprietary devices adjust the resources in systems made of several units. Consumption metering and performance measurement are available and supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, LonWorks. Compatibility with the remote keyboard (up to 8 units). The programmable timer manages a weekly schedule organised into time bands (up to 10 daily time bands associated with different operating set points) to optimise unit performance by minimising power consumption during periods of inactivity. Proprietary self-adaptive logic for the defrosting features the monitoring of several operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 
 
- Electronic control W3000TE
- 
                      find_in_pageFiches Techniquesopenscroll to see all sizesApplication undefined NX-Q-Y Power supply V/ph/Hz PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kW Total power input (1) kW EER (1) kW/kW COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kW EER (1)(2) kW/kW ESEER (1)(2) kW/kW HEATING ONLY (GROSS VALUE) Total heating capacity (3) kW Total power input (3) kW COP (3) kW/kW HEATING ONLY (EN14511 VALUE) Total heating capacity (2)(3) kW COP (2)(3) kW/kW COOLING WITH TOTAL HEAT RECOVERY Cooling capacity (4) kW Total power input (4) kW Recovery heat exchanger capacity (4) kW TER kW/kW ENERGY EFFICIENCY SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281) Process refrigeration at high temperature Prated,c (5) kW SEPR HT (5)(7) SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095) Process refrigeration at medium temperature Prated,c (6) kW SEPR MT (6)(7) SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013) PDesign (8) kW SCOP (8)(9) Performance ηs (8)(10) % Seasonal efficiency class (8) EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow (1) l/s Pressure drop at the heat exchanger (1) kPa HEAT EXCHANGER USER SIDE IN HEATING Water flow (3) l/s Pressure drop at the heat exchanger (3) kPa REFRIGERANT CIRCUIT Compressors nr. N° No. Circuits N° Refrigerant charge kg NOISE LEVEL Sound Pressure (11) dB(A) Sound power level in cooling (12)(13) dB(A) Sound power level in heating (12)(14) dB(A) SIZE AND WEIGHT A (15) mm B (15) mm H (15) mm Operating weight (15) kg 0152P 0182P 0202P 0252P 0262P 0302P 0402P 0502P 0602P 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 43,94 50,85 58,12 64,03 71,56 85,53 110,7 137,9 168,6 12,74 14,83 17,63 19,16 22,23 25,60 33,40 42,28 56,50 3,457 3,432 3,301 3,333 3,225 3,340 3,314 3,260 2,984 43,80 50,60 57,90 63,80 71,40 85,20 110,3 137,4 168,0 3,410 3,380 3,260 3,280 3,180 3,290 3,270 3,210 2,940 4,170 4,110 4,020 4,150 3,970 4,050 4,030 3,970 3,680 46,44 53,18 60,63 67,30 75,18 90,09 115,2 144,8 177,3 13,49 15,30 17,49 19,25 21,42 25,56 32,70 41,33 52,06 3,437 3,477 3,463 3,487 3,514 3,520 3,523 3,506 3,403 46,60 53,40 60,80 67,60 75,50 90,40 115,6 145,3 178,0 3,410 3,440 3,430 3,460 3,480 3,490 3,490 3,470 3,370 44,00 51,12 58,91 64,26 73,07 86,88 111,9 139,7 176,5 11,56 13,39 15,74 17,32 19,83 23,44 30,46 39,51 50,69 54,86 63,71 73,71 80,54 91,71 108,9 140,5 176,8 224,1 8,526 8,567 8,446 8,370 8,323 8,368 8,275 8,013 7,901 33,2 38,2 43,6 49,4 55,6 65,8 83,0 106 135 3,59 3,60 3,63 3,75 3,77 3,71 3,69 3,66 3,64 141 141 142 147 148 145 144 143 143 A+ A+ A+ A+ A+ A+ - - - 2,101 2,432 2,780 3,062 3,422 4,090 5,292 6,592 8,061 14,7 19,7 15,8 19,2 17,1 19,4 22,3 26,2 31,8 2,242 2,567 2,927 3,249 3,629 4,349 5,563 6,992 8,561 16,7 21,9 17,5 21,6 19,3 21,9 24,6 29,5 35,9 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 20,8 22,4 22,9 30,2 30,9 37,1 53,5 64,8 64,9 53 53 53 53 53 54 55 56 56 85 85 85 85 85 86 87 88 88 85 85 85 85 85 86 87 88 88 2625 2625 2625 2625 2625 3250 3875 4500 4500 1350 1350 1350 1350 1350 1350 1350 1350 1350 2070 2070 2070 2070 2070 2070 2070 2070 2070 850 870 890 960 970 1130 1430 1670 1730 openscroll to see all sizesApplication undefined NX-Q-Y /SL Power supply V/ph/Hz PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kW Total power input (1) kW EER (1) kW/kW COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kW EER (1)(2) kW/kW ESEER (1)(2) kW/kW HEATING ONLY (GROSS VALUE) Total heating capacity (3) kW Total power input (3) kW COP (3) kW/kW HEATING ONLY (EN14511 VALUE) Total heating capacity (2)(3) kW COP (2)(3) kW/kW COOLING WITH TOTAL HEAT RECOVERY Cooling capacity (4) kW Total power input (4) kW Recovery heat exchanger capacity (4) kW TER kW/kW ENERGY EFFICIENCY SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281) Process refrigeration at high temperature Prated,c (5) kW SEPR HT (5)(7) SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095) Process refrigeration at medium temperature Prated,c (6) kW SEPR MT (6)(7) SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013) PDesign (8) kW SCOP (8)(9) Performance ηs (8)(10) % Seasonal efficiency class (8) EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow (1) l/s Pressure drop at the heat exchanger (1) kPa HEAT EXCHANGER USER SIDE IN HEATING Water flow (3) l/s Pressure drop at the heat exchanger (3) kPa REFRIGERANT CIRCUIT Compressors nr. N° No. Circuits N° Refrigerant charge kg NOISE LEVEL Sound Pressure (11) dB(A) Sound power level in cooling (12)(13) dB(A) Sound power level in heating (12)(14) dB(A) SIZE AND WEIGHT A (15) mm B (15) mm H (15) mm Operating weight (15) kg 0152P 0182P 0202P 0252P 0262P 0302P 0402P 0502P 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 43,20 49,82 58,48 63,18 71,56 84,78 108,5 130,7 12,48 14,69 17,25 19,36 22,03 25,52 33,44 44,29 3,456 3,388 3,382 3,258 3,255 3,325 3,249 2,950 43,10 49,60 58,30 63,00 71,40 84,50 108,2 130,3 3,410 3,330 3,340 3,210 3,210 3,280 3,210 2,910 4,240 4,130 4,140 4,070 4,030 4,060 4,000 3,680 46,53 53,32 62,15 67,14 76,80 91,15 116,3 141,2 12,89 14,71 17,33 19,05 21,28 25,19 32,31 40,01 3,605 3,626 3,595 3,513 3,606 3,615 3,601 3,530 46,70 53,50 62,40 67,40 77,10 91,40 116,7 141,7 3,570 3,590 3,560 3,480 3,570 3,580 3,570 3,500 44,00 51,12 58,91 64,26 73,07 86,88 111,9 139,7 11,56 13,39 15,74 17,32 19,83 23,44 30,46 39,51 54,86 63,71 73,71 80,54 91,71 108,9 140,5 176,8 8,526 8,567 8,446 8,370 8,323 8,368 8,275 8,013 33,2 38,6 45,5 48,9 56,4 66,7 84,3 105 3,81 3,81 3,80 3,78 3,88 3,83 3,82 3,75 150 150 149 148 152 150 150 147 A++ A++ A+ A+ A++ A++ - - 2,066 2,382 2,797 3,021 3,422 4,054 5,188 6,252 14,2 18,9 16,0 18,7 17,1 19,0 21,4 23,6 2,246 2,574 3,000 3,241 3,707 4,400 5,615 6,818 16,8 22,1 18,4 21,5 20,1 22,4 25,1 28,0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 27,1 28,7 28,8 29,9 42,0 48,9 63,1 63,2 47 47 48 48 48 49 50 52 79 79 80 80 80 81 82 84 79 79 80 80 80 81 82 84 2625 2625 3250 3250 3250 3875 4500 4500 1350 1350 1350 1350 1350 1350 1350 1350 2070 2070 2070 2070 2070 2070 2070 2070 890 910 1000 1030 1090 1270 1610 1680 
- 
                      picture_as_pdfTéléchargement- 
                                    picture_as_pdf
                                    GENERAL CATALOGUES
                                    COMFORT PRODUCT GUIDE cloud_download
 May 2020
- 
                                    picture_as_pdf
                                    GENERAL CATALOGUES
                                    PROCESS PRODUCT GUIDE cloud_download
 March 2020
- 
                                    picture_as_pdf
                                    BROCHURES
                                    IT COOLING PRODUCT OVERVIEW cloud_download
 January 2020
- 
                                    picture_as_pdf
                                    BROCHURES
                                    INTEGRA FULL LINE BROCHURE cloud_download
 November 2019
- 
                                    picture_as_pdf
                                    BROCHURES
                                    INTEGRA PROCESS cloud_download
 July 2019
- 
                                    picture_as_pdf
                                    PROJECT FOCUS
                                    CAPITEC cloud_download
 August 2020
- 
                                    picture_as_pdf
                                    PROJECT FOCUS
                                    TOYOTA MOTOR ITALIA cloud_download
 August 2020
- 
                                    picture_as_pdf
                                    PRODUCT OVERVIEW
                                    COMFORT OVERVIEW cloud_download
 March 2020
- 
                                    picture_as_pdf
                                    PRODUCT OVERVIEW
                                    PROCESS OVERVIEW cloud_download
 March 2020
- 
                                    picture_as_pdf
                                    SELECTION SOFTWARE
                                    ELCA WORLD cloud_download
 April 2020
- 
                                    picture_as_pdf
                                    SELECTION SOFTWARE
                                    AHU SELECTION SOFWARE cloud_download
 June 2019
 
- 
                                    picture_as_pdf
                                    GENERAL CATALOGUES
                                    
 
			