NX-Q-Y 0152P - 0602P
INTEGRA unit for 4-pipe systems, air source for outdoor installation
43,9 - 169 kW
-
format_align_leftDescriptionMulti-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. Unit with two independent refrigerant circuits, each circuit works with an hermetic rotary Scroll compressors using R410A, axial fans, braze-welded plate-type exchanger and thermal expansion valve.
Versions
- - - Basic
- SL - Super-low noise version
Configurations
- - - Basic function
Features
- UNIQUE PROPOSAL
Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting - ENERGY SAVING
Energy saving guaranteed by the advanced operation’s logic. The best operation mode is set completely automatically and independently by the unit’s controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be - ErP READY
The highest level of efficiency at part load can meet and exceed the minimum seasonal efficiency for heating, SCOP (only for reversible units) and for process cooling, SEPR, in accordance with the eco-sustainable design requirements for all products using energy. - INTEGRATED HYDRONIC GROUP
The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving both low or high head, fixed or variable speed, available for both plant and recovery circuits (up to 4 pumps). - WIDE OPERATING RANGE
The accurate condensation control (variable fan speed regulation as per standard on every model) and devoted kits allow unit's operation from -10°C to 46°C of outdoor air temperature, from -8°C to 18°C of evaporator leaving water temperature and hot water up to 55°C.
Accessories
- Touch Screen visual display
- Set-up for remote connectivity with ModBus/Echelon protocol cards
- Hydronic kit available in different configurations with 1 or 2 pumps fixed speed or variable speed, for achieving both low or high head, available for both plant and recovery circuits.
- EC fans with electronic DC brushless motor
- LOW NOISE KIT (only on no silenced versions)
- Soft starters
- Electronic expansion valve
- - - Basic
-
keyboard_hideContrôles
Control
- Electronic control W3000TE
W3000TE controller feature a large format keyboard with wide LCD display in order to ensure an easy access to the machine setup and a complete view of unit's status. The assessment and intervention on the unit is managed through a multi-level menu, with selectable user’s language. The led icons immediately show the operating status of various components.As alternative, the innovative KIPlink user interface allows one to operate on the unit directly from the smartphone or tablet. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. Complete alarm management system is available, with the “black-box” and the alarm history display functions. Optional proprietary devices adjust the resources in systems made of several units. Consumption metering and performance measurement are available and supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, LonWorks. Compatibility with the remote keyboard (up to 8 units). The programmable timer manages a weekly schedule organised into time bands (up to 10 daily time bands associated with different operating set points) to optimise unit performance by minimising power consumption during periods of inactivity. Proprietary self-adaptive logic for the defrosting features the monitoring of several operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.
- Electronic control W3000TE
-
find_in_pageFiches Techniquesopenscroll to see all sizes
Application undefined
NX-Q-Y
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
HEATING ONLY (GROSS VALUE)
Total heating capacity
(3)
kW
Total power input
(3)
kW
COP
(3)
kW/kW
HEATING ONLY (EN14511 VALUE)
Total heating capacity
(2)(3)
kW
COP
(2)(3)
kW/kW
COOLING WITH TOTAL HEAT RECOVERY
Cooling capacity
(4)
kW
Total power input
(4)
kW
Recovery heat exchanger capacity
(4)
kW
TER
kW/kW
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(5)
kW
SEPR HT
(5)(7)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(6)
kW
SEPR MT
(6)(7)
SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013)
PDesign
(8)
kW
SCOP
(8)(9)
Performance ηs
(8)(10)
%
Seasonal efficiency class
(8)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
HEAT EXCHANGER USER SIDE IN HEATING
Water flow
(3)
l/s
Pressure drop at the heat exchanger
(3)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(11)
dB(A)
Sound power level in cooling
(12)(13)
dB(A)
Sound power level in heating
(12)(14)
dB(A)
SIZE AND WEIGHT
A
(15)
mm
B
(15)
mm
H
(15)
mm
Operating weight
(15)
kg
0152P
0182P
0202P
0252P
0262P
0302P
0402P
0502P
0602P
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
43,94
50,85
58,12
64,03
71,56
85,53
110,7
137,9
168,6
12,74
14,83
17,63
19,16
22,23
25,60
33,40
42,28
56,50
3,457
3,432
3,301
3,333
3,225
3,340
3,314
3,260
2,984
43,80
50,60
57,90
63,80
71,40
85,20
110,3
137,4
168,0
3,410
3,380
3,260
3,280
3,180
3,290
3,270
3,210
2,940
4,170
4,110
4,020
4,150
3,970
4,050
4,030
3,970
3,680
46,44
53,18
60,63
67,30
75,18
90,09
115,2
144,8
177,3
13,49
15,30
17,49
19,25
21,42
25,56
32,70
41,33
52,06
3,437
3,477
3,463
3,487
3,514
3,520
3,523
3,506
3,403
46,60
53,40
60,80
67,60
75,50
90,40
115,6
145,3
178,0
3,410
3,440
3,430
3,460
3,480
3,490
3,490
3,470
3,370
44,00
51,12
58,91
64,26
73,07
86,88
111,9
139,7
176,5
11,56
13,39
15,74
17,32
19,83
23,44
30,46
39,51
50,69
54,86
63,71
73,71
80,54
91,71
108,9
140,5
176,8
224,1
8,526
8,567
8,446
8,370
8,323
8,368
8,275
8,013
7,901
33,2
38,2
43,6
49,4
55,6
65,8
83,0
106
135
3,59
3,60
3,63
3,75
3,77
3,71
3,69
3,66
3,64
141
141
142
147
148
145
144
143
143
A+
A+
A+
A+
A+
A+
-
-
-
2,101
2,432
2,780
3,062
3,422
4,090
5,292
6,592
8,061
14,7
19,7
15,8
19,2
17,1
19,4
22,3
26,2
31,8
2,242
2,567
2,927
3,249
3,629
4,349
5,563
6,992
8,561
16,7
21,9
17,5
21,6
19,3
21,9
24,6
29,5
35,9
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
20,8
22,4
22,9
30,2
30,9
37,1
53,5
64,8
64,9
53
53
53
53
53
54
55
56
56
85
85
85
85
85
86
87
88
88
85
85
85
85
85
86
87
88
88
2625
2625
2625
2625
2625
3250
3875
4500
4500
1350
1350
1350
1350
1350
1350
1350
1350
1350
2070
2070
2070
2070
2070
2070
2070
2070
2070
850
870
890
960
970
1130
1430
1670
1730
openscroll to see all sizesApplication undefined
NX-Q-Y /SL
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
HEATING ONLY (GROSS VALUE)
Total heating capacity
(3)
kW
Total power input
(3)
kW
COP
(3)
kW/kW
HEATING ONLY (EN14511 VALUE)
Total heating capacity
(2)(3)
kW
COP
(2)(3)
kW/kW
COOLING WITH TOTAL HEAT RECOVERY
Cooling capacity
(4)
kW
Total power input
(4)
kW
Recovery heat exchanger capacity
(4)
kW
TER
kW/kW
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Process refrigeration at high temperature
Prated,c
(5)
kW
SEPR HT
(5)(7)
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095)
Process refrigeration at medium temperature
Prated,c
(6)
kW
SEPR MT
(6)(7)
SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013)
PDesign
(8)
kW
SCOP
(8)(9)
Performance ηs
(8)(10)
%
Seasonal efficiency class
(8)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
HEAT EXCHANGER USER SIDE IN HEATING
Water flow
(3)
l/s
Pressure drop at the heat exchanger
(3)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(11)
dB(A)
Sound power level in cooling
(12)(13)
dB(A)
Sound power level in heating
(12)(14)
dB(A)
SIZE AND WEIGHT
A
(15)
mm
B
(15)
mm
H
(15)
mm
Operating weight
(15)
kg
0152P
0182P
0202P
0252P
0262P
0302P
0402P
0502P
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
43,20
49,82
58,48
63,18
71,56
84,78
108,5
130,7
12,48
14,69
17,25
19,36
22,03
25,52
33,44
44,29
3,456
3,388
3,382
3,258
3,255
3,325
3,249
2,950
43,10
49,60
58,30
63,00
71,40
84,50
108,2
130,3
3,410
3,330
3,340
3,210
3,210
3,280
3,210
2,910
4,240
4,130
4,140
4,070
4,030
4,060
4,000
3,680
46,53
53,32
62,15
67,14
76,80
91,15
116,3
141,2
12,89
14,71
17,33
19,05
21,28
25,19
32,31
40,01
3,605
3,626
3,595
3,513
3,606
3,615
3,601
3,530
46,70
53,50
62,40
67,40
77,10
91,40
116,7
141,7
3,570
3,590
3,560
3,480
3,570
3,580
3,570
3,500
44,00
51,12
58,91
64,26
73,07
86,88
111,9
139,7
11,56
13,39
15,74
17,32
19,83
23,44
30,46
39,51
54,86
63,71
73,71
80,54
91,71
108,9
140,5
176,8
8,526
8,567
8,446
8,370
8,323
8,368
8,275
8,013
33,2
38,6
45,5
48,9
56,4
66,7
84,3
105
3,81
3,81
3,80
3,78
3,88
3,83
3,82
3,75
150
150
149
148
152
150
150
147
A++
A++
A+
A+
A++
A++
-
-
2,066
2,382
2,797
3,021
3,422
4,054
5,188
6,252
14,2
18,9
16,0
18,7
17,1
19,0
21,4
23,6
2,246
2,574
3,000
3,241
3,707
4,400
5,615
6,818
16,8
22,1
18,4
21,5
20,1
22,4
25,1
28,0
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
27,1
28,7
28,8
29,9
42,0
48,9
63,1
63,2
47
47
48
48
48
49
50
52
79
79
80
80
80
81
82
84
79
79
80
80
80
81
82
84
2625
2625
3250
3250
3250
3875
4500
4500
1350
1350
1350
1350
1350
1350
1350
1350
2070
2070
2070
2070
2070
2070
2070
2070
890
910
1000
1030
1090
1270
1610
1680
-
picture_as_pdfTéléchargement
-
picture_as_pdf
GENERAL CATALOGUES
COMFORT PRODUCT GUIDE
cloud_download
May 2020 -
picture_as_pdf
GENERAL CATALOGUES
PROCESS PRODUCT GUIDE
cloud_download
March 2020 -
picture_as_pdf
BROCHURES
IT COOLING PRODUCT OVERVIEW
cloud_download
January 2020 -
picture_as_pdf
BROCHURES
INTEGRA FULL LINE BROCHURE
cloud_download
November 2019 -
picture_as_pdf
BROCHURES
INTEGRA PROCESS
cloud_download
July 2019 -
picture_as_pdf
PROJECT FOCUS
CAPITEC
cloud_download
August 2020 -
picture_as_pdf
PROJECT FOCUS
TOYOTA MOTOR ITALIA
cloud_download
August 2020 -
picture_as_pdf
PRODUCT OVERVIEW
COMFORT OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
PRODUCT OVERVIEW
PROCESS OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
SELECTION SOFTWARE
ELCA WORLD
cloud_download
April 2020 -
picture_as_pdf
SELECTION SOFTWARE
AHU SELECTION SOFWARE
cloud_download
June 2019
-
picture_as_pdf
GENERAL CATALOGUES