RC - CLIMAVENETA PROCESS GROUPE MULTIFONCTION AIR/EAU ERACS2-Q-G05-Y 1062 - 3222

Image RC – CLIMAVENETA PROCESS GROUPE MULTIFONCTION AIR/EAU ERACS2-Q-G05-Y 1062 – 3222

ERACS2-Q-G05-Y 1062 - 3222
INTEGRA unit for 4-pipe systems, air source for outdoor installation
199 - 826 kW

product iconproduct iconproduct iconproduct iconproduct iconproduct iconproduct icon
  • format_align_leftDescription
    Multi-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. Each circuit works with a semi-hermetic screw compressor using R513A, two shell and tubes heat exchangers shared by both circuits, a cold heat exchanger on plant’s side that acts as an evaporator in the production of cold water, a heat exchanger on plant’s side that works as a condenser in the production of hot water, and a source side coil heat exchanger that works as either condenser or evaporator as required by the loads.

    Versions

    • CA - Class A of efficiency
    • LN-CA - Low Noise, Class A of efficiency
    • SL-CA - Super Low noise version, Class A of efficiency
    • XL-CA - eXtra Low noise version, Class A of efficiency
    • XL-CA-E - eXtra Low noise, Class A enhanced

    Features

    • UNIQUE PROPOSAL
      Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting
    • ENERGY SAVING
      Energy saving guaranteed by the advanced operation’s logic. The best operation mode is set completely automatically and independently by the unit’s controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be
    • WIDE OPERATING RANGE
      Unit´s operation guaranteed with external air temperature down to -10 °C during winter and up to 46 °C during summer.
    • VERSION ´XL-CA-E´ AVAILABLE
      Exclusive Premium version. Together for the first time, the lowest noise level on the market and the maximum efficiency in each operating mode.
    • HOT WATER SUPPLY
      Supply of hot water in use up to 60°C, offering maximum versatility with respect to different plant engineering solutions

    Accessories

    • Hydronic group
    • VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation
    • Electronic expansion valve
    • Set-up for remote connectivity with ModBus/Echelon protocol cards

  • keyboard_hideContrôles

    Control

    • W3000SE Large
      The controller W3000 large offers the latest control and functions specially developed for these units. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. These resources permit to diirectly act on the unit settings through a multilevel menu, available in several languages. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. For multi-units plants a special device to coordinate and manage all the resources is available as an option; energy metering device is even possible as an option. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Temperature regulation managed on the two water circuits, with a proportional logic referred to the return water temperatures. This allows to satisfy simultaneously the different heating- and cooling requests, with no need of mode changeover. Exclusive self-adaptive defrost logic, monitoring multiple operational- and ambient parameters, which allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.
  • find_in_pageFiches Techniques
    openscroll to see all sizes

    Application undefined

    ERACS2-Q-G05-Y /CA

    1062

    1162

    1362

    1562

    1762

    1962

    2022

    2222

    2422

    2622

    2722

    3222

    openscroll to see all sizes

    Application undefined

    ERACS2-Q-G05-Y /LN-CA

    1062

    1162

    1362

    1562

    1762

    1962

    2022

    2222

    2422

    2622

    2722

    3222

    openscroll to see all sizes

    Application undefined

    ERACS2-Q-G05-Y /SL-CA

    1062

    1162

    1362

    1562

    1762

    1962

    2022

    2222

    2422

    2622

    2722

    3222

    openscroll to see all sizes

    Application undefined

    ERACS2-Q-G05-Y /XL-CA

    2022

    2222

    2422

    2622

    2722

    3222

    openscroll to see all sizes

    Application undefined

    ERACS2-Q-G05-Y /XL-CA-E

    1062

    1162

    1362

    1562

    1762

    2022

    2222

    2422

    2622

  • picture_as_pdfTéléchargement
    • picture_as_pdf GENERAL CATALOGUES

      COMFORT PRODUCT GUIDE
      May 2020

      cloud_download
    • picture_as_pdf GENERAL CATALOGUES

      PROCESS PRODUCT GUIDE
      March 2020

      cloud_download
    • picture_as_pdf BROCHURES

      IT COOLING PRODUCT OVERVIEW
      January 2020

      cloud_download
    • picture_as_pdf BROCHURES

      INTEGRA FULL LINE BROCHURE
      November 2019

      cloud_download
    • picture_as_pdf BROCHURES

      INTEGRA PROCESS
      July 2019

      cloud_download
    • picture_as_pdf PROJECT FOCUS

      CAPITEC
      August 2020

      cloud_download
    • picture_as_pdf PROJECT FOCUS

      TOYOTA MOTOR ITALIA
      August 2020

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      COMFORT OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      PROCESS OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 813/2013

      ERACS2-Q-G05-Y SCOP
      February 2019

      cloud_download
    • picture_as_pdf TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 2016/2281

      ERACS2-Q-G05-Y SEPR-HT
      February 2019

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      ELCA WORLD
      April 2020

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      AHU SELECTION SOFWARE
      June 2019

      cloud_download