                        ERACS2-Q-G05-Y 1062 - 3222
                        INTEGRA unit for 4-pipe systems, air source for outdoor installation
199 - 826 kW
                    
                    
                    
                    
                    
                    
                - 
                      format_align_leftDescriptionMulti-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. Each circuit works with a semi-hermetic screw compressor using R513A, two shell and tubes heat exchangers shared by both circuits, a cold heat exchanger on plant’s side that acts as an evaporator in the production of cold water, a heat exchanger on plant’s side that works as a condenser in the production of hot water, and a source side coil heat exchanger that works as either condenser or evaporator as required by the loads.Versions - CA - Class A of efficiency
- LN-CA - Low Noise, Class A of efficiency
- SL-CA - Super Low noise version, Class A of efficiency
- XL-CA - eXtra Low noise version, Class A of efficiency
- XL-CA-E - eXtra Low noise, Class A enhanced
 Features - UNIQUE PROPOSAL
 Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting
- ENERGY SAVING
 Energy saving guaranteed by the advanced operation’s logic. The best operation mode is set completely automatically and independently by the unit’s controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be
- WIDE OPERATING RANGE
 Unit´s operation guaranteed with external air temperature down to -10 °C during winter and up to 46 °C during summer.
- VERSION ´XL-CA-E´ AVAILABLE
 Exclusive Premium version. Together for the first time, the lowest noise level on the market and the maximum efficiency in each operating mode.
- HOT WATER SUPPLY
 Supply of hot water in use up to 60°C, offering maximum versatility with respect to different plant engineering solutions
 Accessories - Hydronic group
- VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation
- Electronic expansion valve
- Set-up for remote connectivity with ModBus/Echelon protocol cards
 
 
- CA - Class A of efficiency
- 
                      keyboard_hideContrôlesControl - W3000SE Large
 The controller W3000 large offers the latest control and functions specially developed for these units. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. These resources permit to diirectly act on the unit settings through a multilevel menu, available in several languages. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. For multi-units plants a special device to coordinate and manage all the resources is available as an option; energy metering device is even possible as an option. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Temperature regulation managed on the two water circuits, with a proportional logic referred to the return water temperatures. This allows to satisfy simultaneously the different heating- and cooling requests, with no need of mode changeover. Exclusive self-adaptive defrost logic, monitoring multiple operational- and ambient parameters, which allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 
 
- W3000SE Large
- 
                      find_in_pageFiches Techniquesopenscroll to see all sizesApplication undefined ERACS2-Q-G05-Y /CA Power supply V/ph/Hz PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kW Total power input (1) kW EER (1) kW/kW COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kW EER (1)(2) kW/kW ESEER (1)(2) kW/kW HEATING ONLY (GROSS VALUE) Total heating capacity (3) kW Total power input (3) kW COP (3) kW/kW HEATING ONLY (EN14511 VALUE) Total heating capacity (2)(3) kW COP (2)(3) kW/kW COOLING WITH TOTAL HEAT RECOVERY Cooling capacity (4) kW Total power input (4) kW Recovery heat exchanger capacity (4) kW TER kW/kW ENERGY EFFICIENCY SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281) Process refrigeration at high temperature Prated,c (5) kW SEPR HT (5)(7) SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095) Process refrigeration at medium temperature Prated,c (6) kW SEPR MT (6)(7) SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013) PDesign (8) kW SCOP (8)(9) Performance ηs (8)(10) % Seasonal efficiency class (8) EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow (1) l/s Pressure drop at the heat exchanger (1) kPa HEAT EXCHANGER USER SIDE IN HEATING Water flow (3) l/s Pressure drop at the heat exchanger (3) kPa REFRIGERANT CIRCUIT Compressors nr. N° No. Circuits N° Refrigerant charge kg NOISE LEVEL Sound Pressure (11) dB(A) Sound power level in cooling (12)(13) dB(A) Sound power level in heating (12)(14) dB(A) SIZE AND WEIGHT A (15) mm B (15) mm H (15) mm Operating weight (15) kg 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 210,0 248,3 302,3 329,4 380,3 425,2 482,7 525,0 553,8 624,1 701,4 825,6 74,78 88,09 105,5 113,5 134,1 149,7 161,8 173,6 182,3 209,0 231,2 274,4 2,807 2,818 2,865 2,902 2,836 2,840 2,983 3,024 3,038 2,986 3,034 3,009 209,3 247,4 301,3 328,2 379,0 424,2 481,6 523,7 552,3 622,9 699,7 823,6 2,770 2,780 2,830 2,860 2,800 2,810 2,960 2,990 3,010 2,960 3,000 2,980 - - - - - - - - - - - - 219,8 261,0 311,6 342,6 399,6 438,3 496,9 546,8 576,4 617,8 718,5 833,8 69,66 84,00 95,98 105,5 126,7 135,8 154,8 165,5 175,5 185,2 215,7 249,9 3,154 3,107 3,246 3,247 3,154 3,228 3,210 3,304 3,284 3,336 3,331 3,337 220,5 262,0 312,7 344,0 401,1 439,5 498,1 548,3 578,1 619,0 720,4 835,9 3,130 3,080 3,220 3,220 3,130 3,210 3,190 3,280 3,260 3,320 3,310 3,320 208,6 248,1 304,6 329,4 381,4 427,5 483,5 521,5 550,3 631,2 701,1 826,1 63,13 75,25 90,73 96,42 115,9 126,9 139,3 150,9 159,8 177,6 201,5 238,0 267,9 318,8 389,9 420,0 490,3 546,8 614,5 663,4 700,5 798,1 890,5 1050 7,553 7,539 7,657 7,774 7,522 7,678 7,882 7,853 7,829 8,046 7,901 7,882 699,7 823,6 5,00 5,01 157 213 221 244 285 314 362 391 357 400 3,36 3,20 3,40 3,47 3,35 3,49 3,42 3,54 3,55 3,55 131 125 133 136 131 137 134 139 139 139 - - - - - - - - - - 10,04 11,88 14,46 15,75 18,19 20,33 23,09 25,11 26,49 29,84 33,54 39,48 28,8 40,2 36,6 43,4 40,3 27,9 26,7 29,0 32,3 23,1 30,5 30,9 10,61 12,60 15,04 16,54 19,29 21,16 23,99 26,39 27,82 29,82 34,68 40,25 32,1 45,2 39,6 47,9 45,3 30,2 28,8 32,1 35,6 23,1 32,6 32,1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 108 129 155 184 191 198 219 242 276 291 322 380 65 65 65 66 66 66 66 68 68 68 68 69 97 97 97 98 99 99 99 101 101 101 101 102 97 97 97 98 99 99 99 101 101 101 101 102 4610 4610 5610 5610 6610 6610 6300 7200 7200 7200 8400 9700 2220 2220 2220 2220 2220 2220 2260 2260 2260 2260 2260 2260 2150 2420 2430 2430 2430 2430 2350 2350 2350 2350 2350 2350 3600 3870 4620 5040 5520 5670 7580 8060 8160 8600 9160 11380 openscroll to see all sizesApplication undefined ERACS2-Q-G05-Y /LN-CA Power supply V/ph/Hz PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kW Total power input (1) kW EER (1) kW/kW COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kW EER (1)(2) kW/kW ESEER (1)(2) kW/kW HEATING ONLY (GROSS VALUE) Total heating capacity (3) kW Total power input (3) kW COP (3) kW/kW HEATING ONLY (EN14511 VALUE) Total heating capacity (2)(3) kW COP (2)(3) kW/kW COOLING WITH TOTAL HEAT RECOVERY Cooling capacity (4) kW Total power input (4) kW Recovery heat exchanger capacity (4) kW TER kW/kW ENERGY EFFICIENCY SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281) Process refrigeration at high temperature Prated,c (5) kW SEPR HT (5)(7) SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095) Process refrigeration at medium temperature Prated,c (6) kW SEPR MT (6)(7) SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013) PDesign (8) kW SCOP (8)(9) Performance ηs (8)(10) % Seasonal efficiency class (8) EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow (1) l/s Pressure drop at the heat exchanger (1) kPa HEAT EXCHANGER USER SIDE IN HEATING Water flow (3) l/s Pressure drop at the heat exchanger (3) kPa REFRIGERANT CIRCUIT Compressors nr. N° No. Circuits N° Refrigerant charge kg NOISE LEVEL Sound Pressure (11) dB(A) Sound power level in cooling (12)(13) dB(A) Sound power level in heating (12)(14) dB(A) SIZE AND WEIGHT A (15) mm B (15) mm H (15) mm Operating weight (15) kg 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 204,9 241,0 293,8 321,8 369,3 413,6 468,7 513,4 541,3 603,9 683,8 799,5 73,65 88,06 107,2 113,3 135,7 149,9 169,5 174,5 184,7 214,7 234,7 285,9 2,780 2,736 2,741 2,840 2,721 2,759 2,765 2,942 2,931 2,813 2,914 2,796 204,3 240,1 292,9 320,6 368,1 412,6 467,7 512,2 539,9 602,8 682,2 797,7 2,750 2,700 2,710 2,800 2,690 2,730 2,740 2,910 2,900 2,790 2,890 2,770 - - - - - - - - - - - - 219,8 261,0 311,6 342,6 399,6 438,3 496,9 546,8 576,4 617,8 718,5 833,8 69,66 84,00 95,98 105,5 126,7 135,8 154,8 165,5 175,5 185,2 215,7 249,9 3,154 3,107 3,246 3,247 3,154 3,228 3,210 3,304 3,284 3,336 3,331 3,337 220,5 262,0 312,7 344,0 401,1 439,5 498,1 548,3 578,1 619,0 720,4 835,9 3,130 3,080 3,220 3,220 3,130 3,210 3,190 3,280 3,260 3,320 3,310 3,320 208,6 248,1 304,6 329,4 381,4 427,5 483,5 521,5 550,3 631,2 701,1 826,1 63,13 75,25 90,73 96,42 115,9 126,9 139,3 150,9 159,8 177,6 201,5 238,0 267,9 318,8 389,9 420,0 490,3 546,8 614,5 663,4 700,5 798,1 890,5 1050 7,553 7,539 7,657 7,774 7,522 7,678 7,882 7,853 7,829 8,046 7,901 7,882 682,2 797,7 5,11 5,21 370,7 428,2 3,22 3,22 157 213 221 244 285 314 362 391 357 400 3,36 3,20 3,40 3,47 3,35 3,49 3,42 3,54 3,55 3,55 131 125 133 136 131 137 134 139 139 139 - - - - - - - - - - 9,797 11,52 14,05 15,39 17,66 19,78 22,42 24,55 25,89 28,88 32,70 38,23 27,4 37,9 34,5 41,4 38,0 26,4 25,1 27,7 30,8 21,6 29,0 29,0 10,61 12,60 15,04 16,54 19,29 21,16 23,99 26,39 27,82 29,82 34,68 40,25 32,1 45,2 39,6 47,9 45,3 30,2 28,8 32,1 35,6 23,1 32,6 32,1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 101 129 156 184 197 221 230 236 276 288 322 368 58 59 59 60 59 59 60 62 62 62 62 63 90 91 91 92 92 92 93 95 95 95 95 96 91 92 92 93 93 93 94 96 96 96 96 97 4610 4610 5610 5610 6610 6610 6300 7200 7200 7200 8400 9700 2220 2220 2220 2220 2220 2220 2260 2260 2260 2260 2260 2260 2150 2420 2430 2430 2430 2430 2350 2350 2350 2350 2350 2350 3600 3870 4620 5040 5520 5670 7580 8060 8160 8600 9160 11380 openscroll to see all sizesApplication undefined ERACS2-Q-G05-Y /SL-CA Power supply V/ph/Hz PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kW Total power input (1) kW EER (1) kW/kW COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kW EER (1)(2) kW/kW ESEER (1)(2) kW/kW HEATING ONLY (GROSS VALUE) Total heating capacity (3) kW Total power input (3) kW COP (3) kW/kW HEATING ONLY (EN14511 VALUE) Total heating capacity (2)(3) kW COP (2)(3) kW/kW COOLING WITH TOTAL HEAT RECOVERY Cooling capacity (4) kW Total power input (4) kW Recovery heat exchanger capacity (4) kW TER kW/kW ENERGY EFFICIENCY SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281) Process refrigeration at high temperature Prated,c (5) kW SEPR HT (5)(7) SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095) Process refrigeration at medium temperature Prated,c (6) kW SEPR MT (6)(7) SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013) PDesign (8) kW SCOP (8)(9) Performance ηs (8)(10) % Seasonal efficiency class (8) EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow (1) l/s Pressure drop at the heat exchanger (1) kPa HEAT EXCHANGER USER SIDE IN HEATING Water flow (3) l/s Pressure drop at the heat exchanger (3) kPa REFRIGERANT CIRCUIT Compressors nr. N° No. Circuits N° Refrigerant charge kg NOISE LEVEL Sound Pressure (11) dB(A) Sound power level in cooling (12)(13) dB(A) Sound power level in heating (12)(14) dB(A) SIZE AND WEIGHT A (15) mm B (15) mm H (15) mm Operating weight (15) kg 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 199,5 233,2 283,4 313,8 356,0 401,4 464,1 509,0 537,1 597,3 677,7 790,4 75,71 91,26 113,2 117,5 143,1 155,5 172,5 177,2 187,6 218,6 238,5 292,8 2,635 2,554 2,504 2,671 2,488 2,581 2,690 2,872 2,863 2,732 2,842 2,699 198,9 232,4 282,5 312,7 354,9 400,5 463,1 507,8 535,7 596,2 676,1 788,6 2,610 2,520 2,480 2,640 2,460 2,560 2,670 2,850 2,840 2,710 2,820 2,680 - - - - - - - - - - - - 213,3 253,5 303,9 333,4 389,1 426,1 490,7 541,1 569,7 605,5 710,1 823,6 67,43 81,70 93,71 102,5 123,5 132,0 153,4 164,0 174,0 183,4 213,8 247,7 3,165 3,103 3,243 3,253 3,151 3,228 3,199 3,299 3,274 3,302 3,321 3,325 214,0 254,5 304,9 334,7 390,5 427,2 491,9 542,5 571,3 606,7 711,9 825,6 3,140 3,080 3,220 3,220 3,130 3,210 3,180 3,280 3,250 3,290 3,300 3,310 208,6 248,1 304,6 329,4 381,4 427,5 483,5 521,5 550,3 631,2 701,1 826,1 63,13 75,25 90,73 96,42 115,9 126,9 139,3 150,9 159,8 177,6 201,5 238,0 267,9 318,8 389,9 420,0 490,3 546,8 614,5 663,4 700,5 798,1 890,5 1050 7,553 7,539 7,657 7,774 7,522 7,678 7,882 7,853 7,829 8,046 7,901 7,882 676,1 788,6 5,09 5,18 368,4 424,8 3,24 3,22 153 207 217 238 279 307 363 390 359 400 3,36 3,21 3,40 3,48 3,35 3,49 3,44 3,55 3,57 3,56 131 125 133 136 131 137 135 139 140 139 - - - - - - - - - - 9,540 11,15 13,55 15,00 17,02 19,20 22,19 24,34 25,68 28,56 32,41 37,80 26,0 35,4 32,1 39,4 35,3 24,8 24,6 27,3 30,3 21,1 28,5 28,3 10,30 12,24 14,67 16,09 18,78 20,57 23,69 26,12 27,50 29,23 34,28 39,76 30,2 42,7 37,6 45,3 43,0 28,5 28,1 31,4 34,8 22,1 31,8 31,3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 101 122 148 179 186 198 230 236 265 276 299 357 54 55 55 56 55 55 56 58 58 58 58 59 86 87 87 88 88 88 89 91 91 91 91 92 87 88 88 89 89 89 90 92 92 92 92 93 4610 4610 5610 5610 6610 6610 6300 7200 7200 7200 8400 9700 2220 2220 2220 2220 2220 2220 2260 2260 2260 2260 2260 2260 2150 2420 2430 2430 2430 2430 2350 2350 2350 2350 2350 2350 3600 3870 4620 5040 5520 5670 7670 8150 8250 8690 9260 11480 openscroll to see all sizesApplication undefined ERACS2-Q-G05-Y /XL-CA Power supply V/ph/Hz PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kW Total power input (1) kW EER (1) kW/kW COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kW EER (1)(2) kW/kW ESEER (1)(2) kW/kW HEATING ONLY (GROSS VALUE) Total heating capacity (3) kW Total power input (3) kW COP (3) kW/kW HEATING ONLY (EN14511 VALUE) Total heating capacity (2)(3) kW COP (2)(3) kW/kW COOLING WITH TOTAL HEAT RECOVERY Cooling capacity (4) kW Total power input (4) kW Recovery heat exchanger capacity (4) kW TER kW/kW ENERGY EFFICIENCY SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281) Process refrigeration at high temperature Prated,c (5) kW SEPR HT (5)(7) SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095) Process refrigeration at medium temperature Prated,c (6) kW SEPR MT (6)(7) SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013) PDesign (8) kW SCOP (8)(9) Performance ηs (8)(10) % Seasonal efficiency class (8) EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow (1) l/s Pressure drop at the heat exchanger (1) kPa HEAT EXCHANGER USER SIDE IN HEATING Water flow (3) l/s Pressure drop at the heat exchanger (3) kPa REFRIGERANT CIRCUIT Compressors nr. N° No. Circuits N° Refrigerant charge kg NOISE LEVEL Sound Pressure (11) dB(A) Sound power level in cooling (12)(13) dB(A) Sound power level in heating (12)(14) dB(A) SIZE AND WEIGHT A (15) mm B (15) mm H (15) mm Operating weight (15) kg 2022 2222 2422 2622 2722 3222 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 454,5 500,5 528,4 583,9 665,4 772,4 174,0 176,8 187,8 221,1 239,6 299,1 2,612 2,831 2,814 2,641 2,777 2,582 453,5 499,4 527,1 582,9 663,9 770,7 2,590 2,810 2,790 2,620 2,750 2,560 - - - - - - 490,7 541,1 569,7 612,8 710,1 823,6 148,7 158,4 168,4 177,8 207,2 240,2 3,300 3,416 3,383 3,447 3,427 3,429 491,9 542,5 571,3 614,0 711,9 825,6 3,280 3,390 3,360 3,430 3,410 3,410 483,5 521,5 550,3 631,2 701,1 826,1 139,3 150,9 159,8 177,6 201,5 238,0 614,5 663,4 700,5 798,1 890,5 1050 7,882 7,853 7,829 8,046 7,901 7,882 527,1 582,9 663,9 770,7 5,46 5,11 5,24 5,34 287,1 315,8 363,7 418,2 3,69 3,49 3,41 3,38 363 390 3,66 3,82 144 150 - - 21,73 23,93 25,27 27,92 31,82 36,94 23,6 26,4 29,4 20,2 27,4 27,1 23,69 26,12 27,50 29,58 34,28 39,76 28,1 31,4 34,8 22,7 31,8 31,3 2 2 2 2 2 2 2 2 2 2 2 2 213 236 269 276 313 368 52 54 54 54 54 55 85 87 87 87 87 88 86 88 88 88 88 89 6300 7200 7200 7200 8400 9700 2260 2260 2260 2260 2260 2260 2350 2350 2350 2350 2350 2350 7790 8260 8350 8790 9340 11580 openscroll to see all sizesApplication undefined ERACS2-Q-G05-Y /XL-CA-E Power supply V/ph/Hz PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kW Total power input (1) kW EER (1) kW/kW COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kW EER (1)(2) kW/kW ESEER (1)(2) kW/kW HEATING ONLY (GROSS VALUE) Total heating capacity (3) kW Total power input (3) kW COP (3) kW/kW HEATING ONLY (EN14511 VALUE) Total heating capacity (2)(3) kW COP (2)(3) kW/kW COOLING WITH TOTAL HEAT RECOVERY Cooling capacity (4) kW Total power input (4) kW Recovery heat exchanger capacity (4) kW TER kW/kW ENERGY EFFICIENCY SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281) Process refrigeration at high temperature Prated,c (5) kW SEPR HT (5)(7) SEASONAL EFFICIENCY IN COOLING (Reg. EU 2015/1095) Process refrigeration at medium temperature Prated,c (6) kW SEPR MT (6)(7) SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013) PDesign (8) kW SCOP (8)(9) Performance ηs (8)(10) % Seasonal efficiency class (8) EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow (1) l/s Pressure drop at the heat exchanger (1) kPa HEAT EXCHANGER USER SIDE IN HEATING Water flow (3) l/s Pressure drop at the heat exchanger (3) kPa REFRIGERANT CIRCUIT Compressors nr. N° No. Circuits N° Refrigerant charge kg NOISE LEVEL Sound Pressure (11) dB(A) Sound power level in cooling (12)(13) dB(A) Sound power level in heating (12)(14) dB(A) SIZE AND WEIGHT A (15) mm B (15) mm H (15) mm Operating weight (15) kg 1062 1162 1362 1562 1762 2022 2222 2422 2622 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 204,3 247,2 293,3 319,4 366,3 472,5 509,5 541,3 611,3 69,43 80,30 103,8 109,1 132,7 158,5 169,6 176,3 201,4 2,944 3,078 2,826 2,928 2,760 2,981 3,004 3,070 3,035 203,7 246,3 292,4 318,3 365,1 471,4 508,3 539,9 610,1 2,910 3,030 2,790 2,890 2,730 2,950 2,980 3,040 3,010 - - - - - - - - - 220,4 269,9 311,2 343,7 396,8 517,8 557,2 593,9 650,2 65,08 80,96 92,20 99,37 121,2 151,7 160,5 170,7 183,0 3,386 3,332 3,375 3,458 3,274 3,413 3,472 3,479 3,553 221,1 271,0 312,3 345,1 398,3 519,2 558,7 595,7 651,6 3,360 3,300 3,350 3,420 3,250 3,390 3,450 3,450 3,530 208,6 248,1 304,6 329,4 381,4 483,5 521,5 550,3 631,2 63,13 75,25 90,73 96,42 115,9 139,3 150,9 159,8 177,6 267,9 318,8 389,9 420,0 490,3 614,5 663,4 700,5 798,1 7,553 7,539 7,657 7,774 7,522 7,882 7,853 7,829 8,046 539,9 610,1 5,67 5,28 292,2 327,0 3,81 3,58 156 188 221 242 283 367 374 3,74 3,42 3,60 3,81 3,56 3,75 3,78 146 134 141 149 139 147 148 - - - - - - - 9,771 11,82 14,03 15,28 17,52 22,60 24,37 25,89 29,23 27,2 39,8 34,4 40,8 37,4 25,5 27,3 30,8 22,1 10,64 13,03 15,02 16,59 19,15 25,00 26,90 28,67 31,38 32,3 48,4 39,5 48,2 44,7 31,3 33,3 37,8 25,5 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 122 158 198 204 232 242 253 269 291 53 54 54 54 54 53 55 55 55 85 86 86 87 87 86 88 88 88 86 87 87 88 88 87 89 89 89 4610 5610 5610 6610 6610 8400 9300 9300 9300 2220 2220 2220 2220 2220 2260 2260 2260 2260 2420 2430 2430 2430 2430 2350 2350 2350 2350 3900 4490 4830 5590 5730 8510 8720 8890 9400 
- 
                      picture_as_pdfTéléchargement- 
                                    picture_as_pdf
                                    GENERAL CATALOGUES
                                    COMFORT PRODUCT GUIDE cloud_download
 May 2020
- 
                                    picture_as_pdf
                                    GENERAL CATALOGUES
                                    PROCESS PRODUCT GUIDE cloud_download
 March 2020
- 
                                    picture_as_pdf
                                    BROCHURES
                                    IT COOLING PRODUCT OVERVIEW cloud_download
 January 2020
- 
                                    picture_as_pdf
                                    BROCHURES
                                    INTEGRA FULL LINE BROCHURE cloud_download
 November 2019
- 
                                    picture_as_pdf
                                    BROCHURES
                                    INTEGRA PROCESS cloud_download
 July 2019
- 
                                    picture_as_pdf
                                    PROJECT FOCUS
                                    CAPITEC cloud_download
 August 2020
- 
                                    picture_as_pdf
                                    PROJECT FOCUS
                                    TOYOTA MOTOR ITALIA cloud_download
 August 2020
- 
                                    picture_as_pdf
                                    PRODUCT OVERVIEW
                                    COMFORT OVERVIEW cloud_download
 March 2020
- 
                                    picture_as_pdf
                                    PRODUCT OVERVIEW
                                    PROCESS OVERVIEW cloud_download
 March 2020
- 
                                    picture_as_pdf
                                    TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 813/2013
                                    ERACS2-Q-G05-Y SCOP cloud_download
 February 2019
- 
                                    picture_as_pdf
                                    TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 2016/2281
                                    ERACS2-Q-G05-Y SEPR-HT cloud_download
 February 2019
- 
                                    picture_as_pdf
                                    SELECTION SOFTWARE
                                    ELCA WORLD cloud_download
 April 2020
- 
                                    picture_as_pdf
                                    SELECTION SOFTWARE
                                    AHU SELECTION SOFWARE cloud_download
 June 2019
 
- 
                                    picture_as_pdf
                                    GENERAL CATALOGUES
                                    
 
			