Reversible heat pump, water source
5,20 - 33,4 kW

product iconproduct iconproduct iconproduct iconproduct iconproduct iconproduct icon
  • format_align_leftDescription
    The MTD2 water-cooled heat pumps are reversible units for heating, cooling and domestic hot water by external three-way valve (accessory). Both the MTD2 heat pumps are suitable for traditional heating systems and radiant panels. The reversible heat pumps, working with water at lower temperatures, ensure a higher yield and are particularly suitable in new buildings with low energy consumption that point on using renewable energy resources. The installation is greatly simplified through the integration of the group simply by connecting the unit the water plant and the electricity so that it can be put into operation.

    Versions

    • - - Basic

    Features

    • Structure and base in hot-dip galvanised steel with epoxy powder paint finish.
    • High efficiency, low pressure drop AISI 316 stainless steel plate heat exchangers, fitted with heating element to provide frost protection.
    • Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection
    • Case panels are insulated within low noise material for further improvement of silence
    • Rubber vibration damper.
    • Soft starter for 230V/1/50Hz units (ms)
    • Phase sequence control relay for three phase models
    • The water circuit comes complete with:
    • Variable flow circulator for 0011÷0061 models and centrifugal variable flow pump for 0071 ÷ 0121 models, plant side
    • Modulating valve to reduce water consumption (source side).
    • Safety valve
    • Expansion tank
    • Manual filling assembly
    • Pressure gauge
    • Air vent valve
    • Drain valve on both the plant and the source circuits.
    • Differential pressure switch on source side and system side

    Accessories

    • Wired room terminal with backlit display, and with temperature and umidity probe
    • Extension module for system configuration
    • Three-way valve for domestic hot water
    • Electric heater of integration for the heating system
    • Electric heater for hot water cylinder, of integration and for anti-legionellosis
    • Cascade management kit
    • Serial card RS485 for ModBus
    • Buffer tank 35,100,200 liters
    • Hot water cylinder 300,500 liters
    • 300 liters thermal store for domestic hot water, for DOMH2O kit
    • 300,500,1000 liters thermal store for domestic hot water with solar heat exchanger, for DOMH2O kit
    • DOMH2O15 e DOMH2O24 kit for domestic hot water with external plate heat exchanger and pump

  • keyboard_hideContrôles

    Control

    • NADISYSTEM
      Electronic control Nadisystem provides great application flexibility. The remote keyboard kit wired indoor and outdoor temperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room and increasing the energy efficiency. The electronic board allows you to manage: -wired remote control, backlit display complete with remote temperature and humidity probe -outdoor temperature sensor for water plant side modular set point compensation -a zone of direct heating for radiator, floor heating or fan coil -domestic hot water production by external three-way valve (accessory) -Electrical heating element for possible integration and anti-legionella cycle for cylinder -boiler or electric heater in substitution or in addition -the room controller can customise up to six time bands. The presence of the programmable timer allows the creation of an operating profile containing up to 6 time bands. -up to 4 heat pump in cascade (with N-CM component) -several solutions through appropriate configurations of the controller and use of dedicated extension modules (accessorie), up to 5 zone.
  • find_in_pageFiches Techniques
    openscroll to see all sizes

    Application undefined

    WWR MTD2

    0011ms

    0025ms

    0031ms

    0041ms

    0025t

    0031t

    0041t

    0061t

    0071t

    0091t

    0101t

    0121t

  • picture_as_pdfTéléchargement
    • picture_as_pdf GENERAL CATALOGUES

      COMFORT PRODUCT GUIDE
      May 2020

      cloud_download
    • picture_as_pdf GENERAL CATALOGUES

      PROCESS PRODUCT GUIDE
      March 2020

      cloud_download
    • picture_as_pdf BROCHURES

      IT COOLING PRODUCT OVERVIEW
      January 2020

      cloud_download
    • picture_as_pdf PROJECT FOCUS

      CAPITEC
      August 2020

      cloud_download
    • picture_as_pdf PROJECT FOCUS

      TOYOTA MOTOR ITALIA
      August 2020

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      COMFORT OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      PROCESS OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 813/2013

      WWR MTD2 0011MS - 0121TS SCOP
      February 2018

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      ELCA WORLD
      April 2020

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      AHU SELECTION SOFWARE
      June 2019

      cloud_download