RC - CLIMAVENETA CONFORT POMPE A CHALEU AIR/EAU NX-CN 0072 - 1104

Image RC – CLIMAVENETA CONFORT POMPE A CHALEU AIR/EAU NX-CN 0072 – 1104

NX-CN 0072 - 1104
Reversible unit, air source for indoor installation
18,0 - 265 kW

product iconproduct iconproduct iconproduct iconproduct iconproduct iconproduct icon
  • format_align_leftDescription
    Heat pump for indoor installation to produce chilled/hot water with hermetic rotary Scroll compressors, centrifugal plug fans with EC motor, braze-welded plate-type exchanger and thermal expansion valve. Structure and the external paneling made from hot-galvanised metal plate and painted with epoxy powder coat RAL 7035. The panels are easy to remove for quick and easy access to the inside components from either side of the unit. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions.

    Versions

    • K - Standard efficiency
    • SL-K - Super low noise, standard efficiency
    • A - High efficiency

    Configurations

    • - - Basic function
    • D - Partial condensing heat recovery function

    Features

    • HIGH EFFICIENCY
      Very high efficiency at full and partial load, at the highest market levels, thanks to the adopted technological solutions. These units ensure low operating costs and therefore a quick payback time.
    • ErP READY
      The highest level of efficiency at part load can meet and exceed the minimum seasonal efficiency for heating, SCOP according with the eco-sustainable design requirements for all products using energy.
    • PLUG FUN WITH EC MOTOR
      More air flow by smaller diameter. Energy cost saving by highest efficiency at the operating point. Fan is directly coupling with motor, no energy lost due to the transmission (belts and pulleys). External rotor fitted with permanent magnets. Outstanding efficiency even at partial load range, due to the lack of brushes and lower consumption in every working condition in order to achieve a better seasonal efficiency in accordance with ErP Directive.
    • TOTAL VERSATILITY
      Horizontal or vertical air flow.
    • INTEGRATED HYDRONIC MODULE
      The built-in hydronic module already contains the main water circuit components; it is available as option with single or twin in-line pump, for achieving low or high head, fixed or variable speed.

    Accessories

    • Soft starters
    • Set-up for remote connectivity with ModBus, Echelon, Bacnet, Bacnet over-IP.
    • Outside air temperature probe for plant water set point compensation.
    • Horizontal or vertical air outflow
    • Hydronic module available in different configurations with 1 or 2 pumps fixed speed or variable speed, for achieving both low or high head.
    • VPF (Variable Primary Flow) system
    • Electronic expansion valve

  • keyboard_hideContrôles

    Control

    • Electronic control W3000TE
      W3000TE Compact features function controls and LCD display for viewing data and activating the unit, via a multilevel menu, with settable display language. As alternative, the innovative KIPlink user interface allows one to operate on the unit directly from the smartphone or tablet. The controller provides water temperature control for the heating systems, cooling systems (only for reversible units), as well as for domestic hot water (only for reversible units). These different temperatures are managed automatically based on the different conditions in which the system operates, with the possibility to assign specific levels of priority to domestic hot water production, depending on the needs of the application. Regulation based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives, the proportional- or proportional- integral regulations are also available. Complete alarm management system is available, with the “black-box” and the alarm history display functions. For multiple units’ systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Built-in clock can create an operating profile containing up to 4 typical days and 10 time bands, essential for efficient programming of energy production and fundamental for managing the Legionella prevention cycles. Supervision is available either using proprietary devices or by integration into third party systems using ModBus, BACnet, BACnet-over-IP and Echelon LonWorks protocols. A dedicated wall-mounted keypad can be used for remote control of all the functions. Optionally (VPF package), capacity modulation can be integrated with hydraulic flow modulation, thanks to inverter-driven pumps and to specific resources for the hydraulic circuit.
  • find_in_pageFiches Techniques
    openscroll to see all sizes

    Application undefined

    NX-CN /K

    0072

    0092

    0102

    0122

    0152

    0182

    0202

    0232

    0272

    0302

    0352

    0402

    0452

    0502

    0552

    0602

    0702

    0524

    0604

    0704

    0804

    0904

    1004

    1104

    openscroll to see all sizes

    Application undefined

    NX-CN /SL-K

    0072

    0092

    0102

    0122

    0152

    0182

    0202

    0232

    0272

    0302

    0352

    0402

    0452

    0502

    0552

    0602

    0702

    0524

    0604

    0704

    0804

    0904

    1004

    openscroll to see all sizes

    Application undefined

    NX-CN /A

    0072

    0092

    0102

    0122

    0152

    0182

    0202

    0232

    0272

    0302

    0352

    0402

    0452

    0502

    0552

    0602

    0702

    0524

    0604

    0704

    0804

    0904

    1004

  • picture_as_pdfTéléchargement
    • picture_as_pdf GENERAL CATALOGUES

      COMFORT PRODUCT GUIDE
      May 2020

      cloud_download
    • picture_as_pdf GENERAL CATALOGUES

      PROCESS PRODUCT GUIDE
      March 2020

      cloud_download
    • picture_as_pdf BROCHURES

      IT COOLING PRODUCT OVERVIEW
      January 2020

      cloud_download
    • picture_as_pdf BROCHURES

      NX-C(N)
      January 2020

      cloud_download
    • picture_as_pdf PROJECT FOCUS

      CAPITEC
      August 2020

      cloud_download
    • picture_as_pdf PROJECT FOCUS

      TOYOTA MOTOR ITALIA
      August 2020

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      COMFORT OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf PRODUCT OVERVIEW

      PROCESS OVERVIEW
      March 2020

      cloud_download
    • picture_as_pdf TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 813/2013

      NX-CN 0072 - 1104 SCOP
      February 2018

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      ELCA WORLD
      April 2020

      cloud_download
    • picture_as_pdf SELECTION SOFTWARE

      AHU SELECTION SOFWARE
      June 2019

      cloud_download