i-NRG 0061m - 0061t
Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation
14,7 kW
-
format_align_leftDescriptionThe new i-NRG heat pump provides exactly the energy required by the system, perfectly following the real load of the building, thanks to the modulation of the DC inverter fan. DC frequency driven fans and circulating pumps (inverter) for both plant and domestic hot water circuits. i-NRG is the new generation heat pump for all year round operation in any operating mode: single cycle (air conditioning, heating, domestic hot water) as well as combined cycle in total heat recovery (domestic hot water together with cooling). Domestic hot water production is guaranteed by the dedicated exchanger for heat recovery: total, for free domestic hot water production, or partial. Domestic hot water is stored in a properly dimensioned storage tank.Extended operating limits for all year, specially in heating: -Maximum flow temperature 60°C -Maximum external air temperature 45°C -Minimum external air temperature -15°C
Versions
- - - Basic
Features
- Structure and base in hot-dip galvanised steel with epoxy powder paint finish.
- High efficiency and low pressure drop stainless steel AISI 316 plate exchangers (at the domestic hot water side). It is positioned next after the compressor and it ensures the domestic hot water production. The unit has full or partial recovery system, with the constant optimization of efficiency through logic advanced adjusting controller
- High efficiency and low pressure drop stainless steel AISI 316 plate exchangers meet the supply of both hot and cold water for the facility, regardless of the domestic hot water
- DC inverter scroll compressor with self-adaptive capacity adjustment. Reduced inrush current due to modulation by an inverter.
- Electronic expansion valve
- Finned coils made with copper pipes and aluminium fins with large exchange surface area (100% fully quality tested)
- Axial electric fan in continuous current housed in aerodynamic conveyor profile with safety grill.
- Low external air temperature device: continuous fan speed regulation with pressure switch
- The water circuit comes complete with:
- Variable flow circulator plant side, the curves are selected by control. Class A energy efficiency
- Variable flow circulator domestic hot water side. Class A energy efficiency.
- Expansion tank
- Safety valve
- Pressure switch system side
- Pressure gauge
- Manual filling assembly
Accessories
- Wired room terminal with backlit display, and with temperature and umidity probe
- Extension module for system configuration
- Acoustic insulation casing kit (MANDATORY for outside installation)
- Rectangular air ducts kit and grills for indoor installation
- Electric heater of integration for the heating system
- Electric heater for hot water cylinder, of integration and for anti-legionellosis
- Cascade management kit
- Serial card RS485 for ModBus
- i-BT85 85 liters storage tank, to place under the heat pump
- Buffer tank 35,100,200 liters
- Hot water cylinder 300,500 liters
- 300 liters thermal store for domestic hot water, for DOMH2O kit
- 300,500,1000 liters thermal store for domestic hot water with solar heat exchanger, for DOMH2O kit
- DOMH2O15 e DOMH2O24 kit for domestic hot water with external plate heat exchanger and pump
- - - Basic
-
keyboard_hideContrôles
Control
- NADISYSTEM
Electronic control for the dynamic control of delivery temperature water, optimizing indoor comfort and increasing the energy efficiency. The electronic board allows you to manage: -Wired remote control, backlit display and with temperature probe and humidity probe -Outdoor temperature sensor for water plant side modular set point compensation -A zone of direct heating for radiator, floor heating or fan coil and a zone with mix valve for floor heating -Electrical heating element for possible integration and anti-legionella cycle for cylinder -Boiler or electric heater in substitution or in addition-Up to 4 heat pump in cascade (with N-CM component) -Several solutions through appropriate configurations of the controller and use of dedicated extension modules (accessories), up to 5 zones.
- NADISYSTEM
-
find_in_pageFiches Techniquesopenscroll to see all sizes
Application undefined
i-NRG
Power supply
V/ph/Hz
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
HEATING ONLY (GROSS VALUE)
Total heating capacity
(3)
kW
Total power input
(3)
kW
COP
(3)
kW/kW
HEATING ONLY (EN14511 VALUE)
Total heating capacity
(2)(3)
kW
COP
(2)(3)
kW/kW
COOLING WITH TOTAL HEAT RECOVERY
Cooling capacity
(4)
kW
Total power input
(4)
kW
Recovery heat exchanger capacity
(4)
kW
TOTAL RECOVERY ONLY
Total heating capacity
(3)
kW
Total power input
(3)
kW
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Ambient refrigeration
Prated,c
(11)
kW
SEER
(11)(12)
Performance ηs
(11)(13)
%
SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013)
PDesign
(5)
kW
SCOP
(5)(14)
Performance ηs
(5)(15)
%
Seasonal efficiency class
(16)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Available unit's head
(1)
kPa
HEAT EXCHANGER USER SIDE IN HEATING
Water flow
(3)
l/s
Available unit's head
(3)
kPa
HEAT EXCHANGER RECOVERY USER SIDE IN REFRIGERATION
Water flow
(4)
l/s
Pressure drop at the heat exchanger
(4)
kPa
HEAT EXCHANGER RECOVERY USER SIDE IN HEATING
Water flow
(4)
l/s
Pressure drop at the heat exchanger
(4)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound power level in cooling
(6)(7)
dB(A)
Sound power level in heating
(6)(8)
dB(A)
Sound Pressure
(9)
dB(A)
SIZE AND WEIGHT
A
(10)
mm
B
(10)
mm
H
(10)
mm
Operating weight
(10)
kg
0061m
0061t
230/1/50
400/3/50
19,66
19,65
5,378
5,384
3,662
3,662
4,470
4,330
19,70
19,70
3,610
3,610
4,240
4,200
16,24
16,27
4,024
3,956
4,030
4,116
16,20
16,20
3,960
4,030
19,04
19,19
4,347
4,355
23,13
23,28
16,24
16,27
4,024
3,956
11,2
11,2
3,80
3,74
149
147
A+
A+
0,943
0,942
65,1
65,2
0,781
0,783
82,1
82,0
1,116
1,124
62,6
63,4
0,745
0,744
27,9
27,8
1
1
1
1
6,55
6,55
68
69
69
70
52
53
750
750
1050
1050
1600
1600
260
260
-
picture_as_pdfTéléchargement
-
picture_as_pdf
GENERAL CATALOGUES
COMFORT PRODUCT GUIDE
cloud_download
May 2020 -
picture_as_pdf
GENERAL CATALOGUES
PROCESS PRODUCT GUIDE
cloud_download
March 2020 -
picture_as_pdf
BROCHURES
IT COOLING PRODUCT OVERVIEW
cloud_download
January 2020 -
picture_as_pdf
PROJECT FOCUS
CAPITEC
cloud_download
August 2020 -
picture_as_pdf
PROJECT FOCUS
TOYOTA MOTOR ITALIA
cloud_download
August 2020 -
picture_as_pdf
PRODUCT OVERVIEW
COMFORT OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
PRODUCT OVERVIEW
PROCESS OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
SELECTION SOFTWARE
ELCA WORLD
cloud_download
April 2020 -
picture_as_pdf
SELECTION SOFTWARE
AHU SELECTION SOFWARE
cloud_download
June 2019
-
picture_as_pdf
GENERAL CATALOGUES