AWR DHW2 XE 0021m - 0101ts
Reversible heat pump, total heat recovery, air source for outdoor installation
5,80 - 22,8 kW
-
format_align_leftDescriptionPRANA DHW is the new HIGH EFFICIENCY heat pump for all year round operation in any operating mode: single cycle (air conditioning, heating, domestic hot water) as well as combined cycle in total heat recovery (domestic hot water together with cooling). Energy efficiency is highest during the summer cycle, when, thanks to the full recovery of the heat, the production of hot water is free. During the combined use, the DHW exchanger uses the temperature of the discharge gases to gets inside the accumulation sanitary water as high as 65° C. The advanced electronic regulation developed by Climaveneta ensures the highest operational flexibility, fast working condition a significant increase in the overall COP, which go hand in hand with electricity and space reduction.
Versions
- - - Basic
- SL - Super-low noise version
Features
- Structure and base in hot-dip galvanised steel with epoxy powder paint finish.
- High efficiency and low pressure drop stainless steel AISI 316 plate exchangers (at the domestic hot water side). It is positioned next after the compressor and it ensures the domestic hot water production. The unit has full or partial recovery system, with the constant optimization of efficiency through logic advanced adjusting controller
- High efficiency and low pressure drop stainless steel AISI 316 plate exchangers meet the supply of both hot and cold water for the facility, regardless of the domestic hot water
- Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection
- Finned coils made with copper pipes and aluminium fins with large exchange surface area (100% fully quality tested)
- Axial electric fans, external rotor, 6-pole electric motor fitted with thermal protection, housed in aerodynamic conveyor profile with safety grill
- Low external air temperature device: continuous fan speed regulation with pressure switch
- Coil protection grille
- Soft starter for 230V units /ms and 400V units /ts
- The water circuit comes complete with:
- Variable flow circulator plant side, the curves are selected by control. Class A energy efficiency
- Variable flow circulator domestic hot water side. Class A energy efficiency.
- Pressure switch system side
- Expansion tank
- Safety valve
- Manual filling assembly
- Pressure gauge
- Air vent valve (plant side).
Accessories
- Wired room terminal with backlit display, and with temperature and umidity probe
- Extension module for system configuration
- Electric heater of integration for the heating system
- Electric heater for hot water cylinder, of integration and for anti-legionellosis
- Serial card RS485 for ModBus
- Cascade management kit
- Buffer tank 35,100,200 liters
- Hot water cylinder 300,500 liters
- 300 liters thermal store for domestic hot water, for DOMH2O kit
- 300,500,1000 liters thermal store for domestic hot water with solar heat exchanger, for DOMH2O kit
- DOMH2O15 e DOMH2O24 kit for domestic hot water with external plate heat exchanger and pump
- - - Basic
-
keyboard_hideContrôles
Control
- NADISYSTEM
Electronic control for the dynamic control of delivery temperature water, optimizing indoor comfort and increasing the energy efficiency. The electronic board allows you to manage: -Wired remote control, backlit display and with temperature probe and humidity probe -Outdoor temperature sensor for water plant side modular set point compensation -A zone of direct heating for radiator, floor heating or fan coil and a zone with mix valve for floor heating -Electrical heating element for possible integration and anti-legionella cycle for cylinder -Boiler or electric heater in substitution or in addition-Up to 4 heat pump in cascade (with N-CM component) -Several solutions through appropriate configurations of the controller and use of dedicated extension modules (accessories), up to 5 zones.
- NADISYSTEM
-
find_in_pageFiches Techniquesopenscroll to see all sizes
Application undefined
AWR DHW2 XE / B
Power supply
V/ph/Hz
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
HEATING ONLY (GROSS VALUE)
Total heating capacity
(3)
kW
Total power input
(3)
kW
COP
(3)
kW/kW
HEATING ONLY (EN14511 VALUE)
Total heating capacity
(2)(3)
kW
COP
(2)(3)
kW/kW
COOLING WITH TOTAL HEAT RECOVERY
Cooling capacity
(4)
kW
Total power input
(4)
kW
Recovery heat exchanger capacity
(4)
kW
TOTAL RECOVERY ONLY
Total heating capacity
(3)
kW
Total power input
(3)
kW
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Ambient refrigeration
Prated,c
(11)
kW
SEER
(11)(12)
Performance ηs
(11)(13)
%
SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013)
PDesign
(5)
kW
SCOP
(5)(14)
Performance ηs
(5)(15)
%
Seasonal efficiency class
(16)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Available unit's head
(1)
kPa
HEAT EXCHANGER USER SIDE IN HEATING
Water flow
(3)
l/s
Available unit's head
(3)
kPa
HEAT EXCHANGER RECOVERY USER SIDE IN REFRIGERATION
Water flow
(4)
l/s
Pressure drop at the heat exchanger
(4)
kPa
HEAT EXCHANGER RECOVERY USER SIDE IN HEATING
Water flow
(4)
l/s
Pressure drop at the heat exchanger
(4)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound power level in cooling
(6)(7)
dB(A)
Sound power level in heating
(6)(8)
dB(A)
Sound Pressure
(9)
dB(A)
SIZE AND WEIGHT
A
(10)
mm
B
(10)
mm
H
(10)
mm
Operating weight
(10)
kg
0021m
0025m
0041m
0025t
0041t
230/1/50
230/1/50
230/1/50
400/3/50
400/3/50
8,210
9,764
13,90
9,784
13,92
2,178
2,597
3,676
2,498
3,617
3,766
3,754
3,777
3,912
3,840
8,220
9,790
13,90
9,810
13,90
3,830
3,830
3,850
3,990
3,910
3,090
3,150
3,310
3,280
3,380
7,591
8,996
12,86
8,842
12,60
1,866
2,174
3,060
2,085
2,987
4,059
4,147
4,216
4,250
4,214
7,580
8,960
12,80
8,810
12,60
4,140
4,190
4,270
4,300
4,290
7,202
8,764
12,75
8,728
12,76
2,015
2,350
3,435
2,348
3,311
9,096
10,97
15,98
10,93
15,87
7,591
8,996
12,86
8,842
12,60
1,866
2,174
3,060
2,085
2,987
5,83
6,01
9,49
5,75
9,33
3,23
3,20
3,41
3,25
3,43
126
125
134
127
134
A+
A+
A+
A+
A+
0,394
0,468
0,667
0,469
0,667
51,7
91,7
74,3
91,6
74,2
0,365
0,433
0,619
0,425
0,606
54,1
95,5
80,3
96,2
81,7
0,439
0,530
0,771
0,528
0,766
14,2
14,8
19,3
14,7
19,1
0,346
0,414
0,595
0,410
0,588
8,79
9,04
11,5
8,86
11,3
1
1
1
1
1
1
1
1
1
1
5,76
6,36
13,0
6,36
13,0
69
70
71
70
71
65
70
70
65
70
54
55
55
55
55
1250
1250
1700
1250
1700
420
420
650
420
650
1125
1125
1200
1125
1200
165
165
295
165
295
openscroll to see all sizesApplication undefined
AWR DHW2 XE / SL
Power supply
V/ph/Hz
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
HEATING ONLY (GROSS VALUE)
Total heating capacity
(3)
kW
Total power input
(3)
kW
COP
(3)
kW/kW
HEATING ONLY (EN14511 VALUE)
Total heating capacity
(2)(3)
kW
COP
(2)(3)
kW/kW
COOLING WITH TOTAL HEAT RECOVERY
Cooling capacity
(4)
kW
Total power input
(4)
kW
Recovery heat exchanger capacity
(4)
kW
TOTAL RECOVERY ONLY
Total heating capacity
(3)
kW
Total power input
(3)
kW
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Ambient refrigeration
Prated,c
(11)
kW
SEER
(11)(12)
Performance ηs
(11)(13)
%
SEASONAL EFFICIENCY IN HEATING (Reg. EU 813/2013)
PDesign
(5)
kW
SCOP
(5)(14)
Performance ηs
(5)(15)
%
Seasonal efficiency class
(16)
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Available unit's head
(1)
kPa
HEAT EXCHANGER USER SIDE IN HEATING
Water flow
(3)
l/s
Available unit's head
(3)
kPa
HEAT EXCHANGER RECOVERY USER SIDE IN REFRIGERATION
Water flow
(4)
l/s
Pressure drop at the heat exchanger
(4)
kPa
HEAT EXCHANGER RECOVERY USER SIDE IN HEATING
Water flow
(4)
l/s
Pressure drop at the heat exchanger
(4)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound power level in cooling
(6)(7)
dB(A)
Sound power level in heating
(6)(8)
dB(A)
Sound Pressure
(9)
dB(A)
SIZE AND WEIGHT
A
(10)
mm
B
(10)
mm
H
(10)
mm
Operating weight
(10)
kg
0065t
0101t
400/3/50
400/3/50
20,96
31,31
5,574
8,471
3,770
3,695
21,10
31,40
3,800
3,750
3,300
3,140
19,40
29,38
4,682
7,063
4,145
4,164
19,30
29,30
4,130
4,190
20,45
30,41
4,674
6,779
24,85
36,78
19,40
29,38
4,682
7,063
15,1
20,5
3,43
3,30
134
129
A+
A+
1,005
1,501
102
93,5
0,933
1,414
104
97,0
1,199
1,775
18,2
17,1
0,910
1,377
10,5
10,3
1
1
1
1
16,7
18,0
73
74
74
75
57
58
1700
1700
650
650
1700
1700
348
390
-
picture_as_pdfTéléchargement
-
picture_as_pdf
GENERAL CATALOGUES
COMFORT PRODUCT GUIDE
cloud_download
May 2020 -
picture_as_pdf
GENERAL CATALOGUES
PROCESS PRODUCT GUIDE
cloud_download
March 2020 -
picture_as_pdf
BROCHURES
IT COOLING PRODUCT OVERVIEW
cloud_download
January 2020 -
picture_as_pdf
PROJECT FOCUS
CAPITEC
cloud_download
August 2020 -
picture_as_pdf
PROJECT FOCUS
TOYOTA MOTOR ITALIA
cloud_download
August 2020 -
picture_as_pdf
PRODUCT OVERVIEW
COMFORT OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
PRODUCT OVERVIEW
PROCESS OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
SELECTION SOFTWARE
ELCA WORLD
cloud_download
April 2020 -
picture_as_pdf
SELECTION SOFTWARE
AHU SELECTION SOFWARE
cloud_download
June 2019
-
picture_as_pdf
GENERAL CATALOGUES