NX-G06 0202P - 0812P
Chiller, air source for outdoor installation
49,6 - 218 kW
-
format_align_leftDescriptionOutdoor unit for the production of chilled water with hermetic rotary Scroll compressors, low-GWP and ozone-friendly refrigerant R454B, axial-flow fans, plate heat exchanger, micro-channel full-aluminum air coils and thermostatic or electronic expansion valve, according to the model. The range is composed by units equipped with two compressors in a single-circuit configuration.
Versions
- K - Key efficiency, compact version
- LN-K - Low Noise, Key efficiency and compact version
- SL-K - Super Low noise, Key efficiency and compact version
- CA - Class A of efficiency
- LN-CA - Low Noise, Class A of efficiency
- SL-CA - Super Low noise version, Class A of efficiency
Configurations
- - - Basic function
- D - Partial condensing heat recovery function
Features
- LOW GWP REFRIGERANT
The new generation refrigerant R454B is the most eco-sustainable alternative to traditional refrigerant R410A, offering a 76% reduction in terms of GWP (Global Warming Potential GWP of R454B = 466, GWP of R410A = 1924 as per IPCC rev. 5th) and zero impact on the ozone layer. - CLASS A EFFICIENCY
The full range is available with the Class A efficiency rating. Thanks to the generous sizing of the heat exchangers and an accurate control of the fan speed, the CA versions grant a premium level efficiency in every noise configuration. - ALUMINIUM MICRO-CHANNEL HEAT EXCHANGERS
The full aluminium micro-channel condenser coils deliver high efficiency whilst ensuring a reduced refrigerant volume and a lower unit weight. The e-coating protection (optional) grants the highest level of resistance to corrosion in any condition, even in the most aggressive environments. - ELECTRONIC EXPANSION VALVE
The use of the electronic expansion valve generates considerable benefits, especially in cases of variable demand and different external conditions. It has been introduced into these units as a result of accurate design choices concerning the cooling circuit and the optimisation of operation in various different working conditions. The electronic expansion valve comes standard in the high-efficieny CA version. - WIDE OPERATING RANGE
Full load operation is ensured with outdoor air temperature up to 46°C, partial load operation is possible up to or even beyond 50°C. The unit can produce chilled water at negative temperature (down to -10°C of leaving water temperature). Dedicated accessories allow the unit operation down to -20°C of outdoor air temperature. - INTEGRATED HYDRONIC GROUP
The optional built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head.
Accessories
- Microchannel coils with e-coating protection
- Traditional coils with copper tubes and alluminium fins, also available with prepainted fins or Fin Guard Silver protective treatment.
- Copper-Copper heat exchanger coils
- Compressor power factor correction
- Soft start
- Compressor suction and discharge valves
- High and low pressure gauges
- DVVF and DVV2F devices for low air temperature operation
- Hydronic module with 1 or 2 pumps, high or low head. Buffer tank available.
- Anti-intrusion grills
- EC fans with electronic DC brushless motor
- KIPlink user interface
- User Limit Control (U.L.C.) allows the safe startup of the unit in critical conditions of water and air temperature.
- Night mode is a system setting to limit maximum noise level of the unit.
- Leak detector
- K - Key efficiency, compact version
-
keyboard_hideContrôles
Control
- Electronic control W3000 / W3000+
The controller is available in two different versions according to the unit’s model, both with Compact keyboard: W3000 : It features an easy-to-use interface and a complete LCD display that allows consulting and intervening on the unit by means of a multi-language menu, available in three languages: Italian, English and a further language among French, Spanish, German, Russian and Swedish. The clock card allows to consult the alarm history from the keyboard. W3000+ : It features an easy-to-use interface and a complete LCD display that allows consulting and intervening on the unit by means of a multi-language menu (19 languages are available). The diagnostics includes a complete alarm management, with the “black-box” and the alarm history display for enhanced analysis of the unit operation. The programmable timer manages a weekly schedule organized into time bands to optimise unit performance by minimising power consumption during periods of inactivity. Up to 10 daily time bands can be associated with different operating set points. As option, the KIPlink is available - Keyboard In Your Pocket - is the innovative user interface based on WiFi technology that allows one to operate on the unit directly from the smartphone or tablet. On both versions, the regulation is based on the patented “Quickmind” water temperature regulation logic uses self-adapting control to maintain flow temperatures and optimise performance even in low water content scenarios. As an alternative, the proportional or proportional-integral regulations are also available. Optional proprietary devices can perform the adjustment of the resources in systems made of several units. Consumption metering and performance measurement are possible as well. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, LonWorks. Compatibility with the remote keyboard (up to 8 units). The defrosting (reversible unit only) follows a proprietary self-adaptive logic, which features the monitoring of several operational parameters, therefore reducing the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.
- Electronic control W3000 / W3000+
-
find_in_pageFiches Techniquesopenscroll to see all sizes
Application undefined
NX-G06/K
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Ambient refrigeration
Prated,c
(7)
kW
SEER
(7)(8)
Performance ηs
(7)(9)
%
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202P
0252P
0262P
0302P
0352P
0402P
0452P
0502P
0552P
0602P
0702P
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
49,84
56,52
62,39
74,51
84,98
97,89
109,9
122,3
138,5
159,0
181,9
16,80
19,05
21,78
24,87
29,10
33,00
37,44
41,84
48,66
53,78
63,24
2,964
2,958
2,862
2,992
2,921
2,967
2,939
2,926
2,844
2,955
2,878
49,70
56,40
62,30
74,40
84,70
97,60
109,6
122,0
138,2
158,7
181,6
2,920
2,930
2,830
2,960
2,860
2,910
2,880
2,870
2,800
2,910
2,830
-
-
-
-
-
-
-
-
-
-
-
49,7
56,4
62,3
74,4
84,7
97,6
110
122
138
159
182
4,01
4,07
4,02
4,00
4,05
3,87
3,85
3,85
3,90
3,86
3,88
157
160
158
157
159
152
151
151
153
151
152
2,383
2,703
2,984
3,563
4,064
4,681
5,255
5,850
6,623
7,605
8,698
33,4
30,8
30,6
31,3
49,9
46,0
47,2
45,2
48,0
45,4
45,9
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
5,60
7,20
7,30
8,60
9,20
11,0
12,2
12,4
13,9
15,9
16,0
52
52
52
53
54
56
56
56
57
58
58
84
84
84
85
86
88
88
88
89
90
90
1825
2395
2395
2395
2395
2825
2825
2825
3360
3980
3980
1195
1195
1195
1195
1195
1195
1195
1195
1195
1195
1195
1865
1865
1865
1865
1865
1980
1980
1980
1980
1980
1980
520
570
580
600
610
700
790
860
930
1060
1080
openscroll to see all sizesApplication undefined
NX-G06/LN-K
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Ambient refrigeration
Prated,c
(7)
kW
SEER
(7)(8)
Performance ηs
(7)(9)
%
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202P
0252P
0262P
0302P
0352P
0402P
0452P
0502P
0552P
0602P
0702P
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
49,63
56,41
62,90
71,67
86,34
95,43
108,3
120,2
134,3
156,3
172,2
17,20
18,90
21,49
26,26
28,90
33,42
36,49
41,05
49,15
53,99
65,29
2,884
2,984
2,926
2,726
2,986
2,856
2,967
2,925
2,735
2,894
2,637
49,50
56,30
62,80
71,50
86,10
95,20
108,0
119,9
133,9
156,0
171,9
2,850
2,950
2,890
2,700
2,930
2,810
2,920
2,880
2,690
2,850
2,600
-
-
-
-
-
-
-
-
-
-
-
49,5
56,3
62,8
71,5
86,1
95,2
108
120
134
156
172
4,01
4,06
4,07
3,98
3,88
3,88
3,94
3,96
3,99
3,93
3,86
157
159
160
156
152
152
155
155
157
154
151
2,373
2,697
3,008
3,427
4,129
4,564
5,181
5,749
6,422
7,473
8,237
33,1
30,6
31,1
28,9
51,5
43,7
45,9
43,7
45,2
43,9
41,2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
6,10
7,50
7,60
8,30
9,80
10,9
12,6
13,6
13,8
15,0
15,4
47
48
48
48
51
51
52
52
52
53
53
79
80
80
80
83
83
84
84
84
85
85
2395
2395
2395
2395
2825
2825
3360
3360
3360
3980
3980
1195
1195
1195
1195
1195
1195
1195
1195
1195
1195
1195
1865
1865
1865
1865
1980
1980
1980
1980
1980
1980
1980
570
600
600
610
730
750
920
990
1010
1110
1120
openscroll to see all sizesApplication undefined
NX-G06/SL-K
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Ambient refrigeration
Prated,c
(7)
kW
SEER
(7)(8)
Performance ηs
(7)(9)
%
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202P
0252P
0262P
0302P
0352P
0402P
0452P
0502P
0552P
0602P
400/3+N/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
50,18
56,53
63,24
74,64
84,96
96,00
108,9
119,4
134,9
146,9
16,89
18,86
21,28
25,45
28,35
32,57
36,52
41,57
48,74
57,31
2,970
2,989
2,967
2,925
3,004
2,945
2,984
2,870
2,770
2,564
50,10
56,40
63,10
74,50
84,70
95,70
108,6
119,0
134,5
146,5
2,930
2,960
2,930
2,900
2,940
2,900
2,930
2,830
2,720
2,530
-
-
-
-
-
-
-
-
-
-
50,1
56,4
63,1
74,5
84,7
95,7
109
119
135
147
4,06
3,89
3,89
3,96
3,97
4,00
4,00
3,94
3,94
3,86
160
153
152
155
156
157
157
155
155
151
2,400
2,703
3,024
3,569
4,063
4,591
5,207
5,708
6,449
7,023
33,9
30,8
31,4
31,4
49,8
44,3
46,4
43,1
45,5
38,7
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
7,00
7,30
8,60
10,0
10,3
12,2
14,0
15,0
15,1
15,4
45
46
46
46
47
48
49
49
50
50
77
78
78
78
79
80
81
81
82
82
2395
2825
2825
2825
3360
3360
3980
3980
3980
3980
1195
1195
1195
1195
1195
1195
1195
1195
1195
1195
1865
1980
1980
1980
1980
1980
1980
1980
1980
1980
590
700
710
710
810
830
990
1060
1070
1110
openscroll to see all sizesApplication undefined
NX-G06/CA
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Ambient refrigeration
Prated,c
(7)
kW
SEER
(7)(8)
Performance ηs
(7)(9)
%
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202P
0252P
0262P
0302P
0352P
0402P
0452P
0502P
0562P
0612P
0712P
0812P
400/3+N/50
400/3+N/50
400/3+N/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
52,80
59,95
66,81
81,64
92,73
103,6
117,0
132,3
153,9
171,3
193,2
218,0
15,59
17,95
20,27
24,80
28,22
31,39
35,66
39,89
45,80
51,88
59,31
65,98
3,385
3,352
3,291
3,290
3,287
3,299
3,277
3,316
3,360
3,301
3,258
3,303
52,70
59,80
66,70
81,40
92,40
103,3
116,8
132,0
153,6
171,0
192,8
217,6
3,330
3,290
3,240
3,240
3,200
3,230
3,210
3,250
3,290
3,240
3,200
3,240
-
-
-
-
-
-
-
-
-
-
-
-
52,7
59,8
66,7
81,4
92,4
103
117
132
154
171
193
218
4,05
4,12
4,16
3,97
3,95
4,02
4,12
3,99
3,99
4,03
4,12
3,94
159
162
163
156
155
158
162
157
157
158
162
155
2,525
2,867
3,195
3,904
4,435
4,956
5,597
6,326
7,361
8,191
9,237
10,43
37,5
34,6
35,1
37,5
59,4
51,6
53,6
52,9
59,3
52,7
51,8
65,9
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
7,30
7,90
8,00
9,30
12,4
12,5
12,9
17,5
19,8
20,3
20,8
23,0
53
53
54
56
56
58
58
58
59
59
60
61
85
85
86
88
88
90
90
90
91
91
92
93
2395
2395
2395
2825
3360
3360
3360
3980
3160
3160
3160
4335
1195
1195
1195
1195
1195
1195
1195
1195
2250
2250
2250
2250
1865
1865
1865
1980
1980
1980
1980
1980
2170
2170
2170
2170
580
590
600
710
780
830
920
1060
1460
1480
1490
1750
openscroll to see all sizesApplication undefined
NX-G06/LN-CA
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Ambient refrigeration
Prated,c
(7)
kW
SEER
(7)(8)
Performance ηs
(7)(9)
%
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202P
0252P
0262P
0302P
0352P
0402P
0452P
0502P
0562P
0612P
0712P
0812P
400/3+N/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
52,81
60,95
67,86
79,36
90,65
103,1
115,8
128,8
147,8
165,8
190,4
212,4
15,98
18,19
20,40
24,17
27,31
31,02
35,29
39,35
43,82
50,64
56,55
62,85
3,300
3,352
3,328
3,281
3,322
3,326
3,280
3,277
3,374
3,277
3,364
3,382
52,70
60,80
67,70
79,20
90,30
102,8
115,4
128,5
147,5
165,5
190,1
212,0
3,250
3,300
3,270
3,230
3,240
3,250
3,210
3,210
3,300
3,220
3,310
3,310
-
-
-
-
-
-
-
-
-
-
-
-
52,7
60,8
67,7
79,2
90,3
103
115
129
148
166
190
212
4,12
3,89
3,92
3,99
4,03
3,91
4,00
4,00
4,27
4,17
4,36
4,14
162
153
154
156
158
153
157
157
168
164
171
162
2,525
2,915
3,245
3,795
4,335
4,932
5,538
6,160
7,067
7,931
9,106
10,16
37,5
35,8
36,2
35,5
56,8
51,1
52,5
50,2
54,7
49,4
50,3
62,6
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
7,20
8,00
10,3
10,4
11,3
13,1
13,1
14,1
23,6
23,7
23,8
25,7
48
49
49
50
52
52
52
53
54
54
55
56
80
81
81
82
84
84
84
85
86
86
87
88
2395
2825
2825
3360
3360
3980
3980
3980
3160
3160
4335
4335
1195
1195
1195
1195
1195
1195
1195
1195
2250
2250
2250
2250
1865
1980
1980
1980
1980
1980
1980
1980
2170
2170
2170
2170
590
700
710
780
820
920
990
1070
1460
1480
1730
1810
openscroll to see all sizesApplication undefined
NX-G06/SL-CA
Power supply
V/ph/Hz
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity
(1)
kW
Total power input
(1)
kW
EER
(1)
kW/kW
ESEER
(1)
kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity
(1)(2)
kW
EER
(1)(2)
kW/kW
ESEER
(1)(2)
kW/kW
Cooling energy class
ENERGY EFFICIENCY
SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)
Ambient refrigeration
Prated,c
(7)
kW
SEER
(7)(8)
Performance ηs
(7)(9)
%
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow
(1)
l/s
Pressure drop at the heat exchanger
(1)
kPa
REFRIGERANT CIRCUIT
Compressors nr.
N°
No. Circuits
N°
Refrigerant charge
kg
NOISE LEVEL
Sound Pressure
(3)
dB(A)
Sound power level in cooling
(4)(5)
dB(A)
SIZE AND WEIGHT
A
(6)
mm
B
(6)
mm
H
(6)
mm
Operating weight
(6)
kg
0202P
0252P
0262P
0302P
0352P
0412P
0462P
0512P
0562P
0612P
0712P
0812P
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
53,11
59,72
66,44
78,67
90,71
101,8
113,9
127,7
145,6
165,4
187,1
208,9
15,93
17,65
19,87
23,73
27,54
30,10
34,29
38,87
43,94
49,10
57,20
63,36
3,340
3,373
3,337
3,321
3,298
3,382
3,321
3,283
3,317
3,369
3,271
3,295
53,00
59,60
66,30
78,50
90,40
101,5
113,5
127,4
145,3
165,1
186,7
208,5
3,280
3,330
3,290
3,260
3,220
3,310
3,250
3,220
3,250
3,310
3,220
3,230
-
-
-
-
-
-
-
-
-
-
-
-
53,0
59,6
66,3
78,5
90,4
102
114
127
145
165
187
209
3,99
3,99
4,05
4,20
4,06
4,16
4,22
4,25
4,30
4,30
4,41
4,21
157
157
159
165
159
163
166
167
169
169
173
165
2,540
2,856
3,177
3,762
4,338
4,867
5,447
6,106
6,962
7,911
8,945
9,989
38,0
34,4
34,7
34,9
56,8
49,7
50,8
49,3
53,1
49,1
48,5
60,5
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
7,70
9,00
9,70
9,80
11,7
14,2
14,9
17,4
21,6
23,5
23,6
27,0
46
47
47
47
48
49
50
50
51
52
53
54
78
79
79
79
80
81
82
82
83
84
85
86
2825
3360
3360
3360
3980
3160
3160
3160
4335
4335
4335
5510
1195
1195
1195
1195
1195
2250
2250
2250
2250
2250
2250
2250
1980
1980
1980
1980
1980
2170
2170
2170
2170
2170
2170
2170
700
790
800
810
890
1280
1370
1440
1690
1750
1770
2070
-
picture_as_pdfTéléchargement
-
picture_as_pdf
BROCHURES
NX-G06 / NX-N G06 2-4-COMPRESSOR UNITS
cloud_download
June 2020 -
picture_as_pdf
BROCHURES
IT COOLING PRODUCT OVERVIEW
cloud_download
January 2020 -
picture_as_pdf
GENERAL CATALOGUES
COMFORT PRODUCT GUIDE
cloud_download
May 2020 -
picture_as_pdf
GENERAL CATALOGUES
PROCESS PRODUCT GUIDE
cloud_download
March 2020 -
picture_as_pdf
PROJECT FOCUS
CAPITEC
cloud_download
August 2020 -
picture_as_pdf
PROJECT FOCUS
TOYOTA MOTOR ITALIA
cloud_download
August 2020 -
picture_as_pdf
PRODUCT OVERVIEW
COMFORT OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
PRODUCT OVERVIEW
PROCESS OVERVIEW
cloud_download
March 2020 -
picture_as_pdf
TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 2016/2281
NX-G06 SEER 2-COMPRESSOR UNITS
cloud_download
July 2019 -
picture_as_pdf
TECHNICAL DOCUMENTATIONS - REGULATION (EU) N. 2016/2281
NX-G06 SEER EC FANS 2-COMPRESSOR UNITS
cloud_download
July 2019 -
picture_as_pdf
R454B SUPPORTING DOCUMENTS
R454B MANUAL
cloud_download
October 2019 -
picture_as_pdf
SELECTION SOFTWARE
ELCA WORLD
cloud_download
April 2020 -
picture_as_pdf
SELECTION SOFTWARE
AHU SELECTION SOFWARE
cloud_download
June 2019
-
picture_as_pdf
BROCHURES